Procedure
Check the position of the mounting profile
on the safety light grid
and slide the mount-
ing profile on both units of the safety light
grid
along to the correct position of the mut-
ing sensor. To do this, loosen the hexagonal
screws. Then tighten up the hexagonal
screws again.
The mounting profiles should be at the
same height.
[1]
[2]
[1] Mounting profile for attaching the muting
sensor
[2] Safety light grid
on mounting surface
Fix the muting sensor with the small plates
to the mounting profile.
[1]
[2]
[1]
[1] Hexagonal screws for attaching the
mounting profile to the safety light grid
[2] Allen screws for attaching the muting
sensor to the mounting profile
6.3
Installation of external muting sensors
When using external muting sensors, position
}
Sensor B1, with transport in one direction
}
Sensors A2 and B1, with transport in two directions
As closely as possible to the safety light grid (see
Distances between muting sensors in the
application example - 4 muting sensors [
32]
).