![Pilz PSEN op2B-2-050/1 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/pilz/psen-op2b-2-050-1/psen-op2b-2-050-1_operating-manual_1556675020.webp)
Function description
Operating Manual PSEN op2B/1 Series
1003357-EN-02
20
CAUTION!
Transport speed too low
If the transport speed is too low, the conveyed material will not trigger a
muting status.
The transport speed should be selected so that the conveyed material
passes the second sensor within a max. 4 s of it being detected by the first
sensor.
CAUTION!
Ending the muting status
Use a mechanical barrier (see diagram) to prevent access to the danger
zone once muting is ended.
Fig.: Application for muting in one direction - Danger zone is safeguarded once muting is ended
}
The muting status is displaying by the muting lamp, which is positioned on the top of
the receiver.
}
If the muting lamp is defective, the muting function cannot be activated. Any attempt to
activate the function will immediately trigger the safety light grid and instantly switch off
the OSSD; the muting lamp fault indicator will also light (seeIndicators for fault dia-
gnostics).