background image

  

3 | 

P a g e

 

 

Standalone Configuration: Static IP ................................................................................. 32 

Accessing FMGuard Web Pages .......................................................................................... 33 

CHAPTER 6: LOG-IN PAGE ......................................................................................................... 34 
CHAPTER 7: DASHBOARD PAGE................................................................................................ 35 

Digital Input (X) ........................................................................................................................ 35 
Analog Input (AI) .................................................................................................................... 36 
Digital Output (Y) .................................................................................................................... 36 

CHAPTER 8: I/O CONFIGURATION PAGE ................................................................................. 37 

Digital Input .............................................................................................................................. 37 
Analog Input ............................................................................................................................ 38 
Digital Output .......................................................................................................................... 40 
Modbus Discrete Inputs .......................................................................................................... 41 

CHAPTER 9: MODBUS CONFIGURATION PAGE ....................................................................... 42 
CHAPTER 10: EMAIL AND SMS ALERTS....................................................................................... 45 
CHAPTER 11: SYSTEM CONFIGURATION ................................................................................... 46 

Device ID .................................................................................................................................. 46 
LAN Configuration .................................................................................................................. 46 
SMS Settings ............................................................................................................................. 47 
NTP Server Settings .................................................................................................................. 48 
Email Settings ........................................................................................................................... 48 
Auto Health Check ................................................................................................................. 49 
Date and Time ......................................................................................................................... 49 
Reporting .................................................................................................................................. 49 
User Authentication ................................................................................................................ 50 
Delete Outbox Content ......................................................................................................... 50 

CHAPTER 12: LOGS ..................................................................................................................... 51 
CHAPTER 13: HELP ....................................................................................................................... 52 

Phone Groups Command ..................................................................................................... 52 
IO Command .......................................................................................................................... 53 
IO Configuration ..................................................................................................................... 54 

Содержание FMGuard FMG-1

Страница 1: ...Document No 2018 0731 003 Revision No 0001 FMGuard Facility Management Controller User Manual Model FMG 1 Please read this user manual carefully before using the device ...

Страница 2: ...5 S2 System LED2 Pattern Overview 16 CHAPTER 4 HARDWARE GUIDE 17 Mounting 17 FMGUARD Installation 17 DC Input 18 Ethernet 18 Antenna 18 Reset Button 18 Battery 19 External Li Ion Battery Optional 19 Battery Selection Jumpers 19 DIP SWITCH 20 Terminal Blocks Signal Overview 21 Digital Inputs with S0 22 S0 compliant inputs IEC62053 31 Class A compatible 22 LCD DISPLAY 23 CHAPTER 5 SOFTWARE CONFIGURA...

Страница 3: ...g Input 38 Digital Output 40 Modbus Discrete Inputs 41 CHAPTER 9 MODBUS CONFIGURATION PAGE 42 CHAPTER 10 EMAIL AND SMS ALERTS 45 CHAPTER 11 SYSTEM CONFIGURATION 46 Device ID 46 LAN Configuration 46 SMS Settings 47 NTP Server Settings 48 Email Settings 48 Auto Health Check 49 Date and Time 49 Reporting 49 User Authentication 50 Delete Outbox Content 50 CHAPTER 12 LOGS 51 CHAPTER 13 HELP 52 Phone Gr...

Страница 4: ...4 P a g e Repeat Configuration 55 Remote SMS command Benefits 55 ...

Страница 5: ...utilize fully the capability of the product FMGuard is a standalone alarm monitoring controller with 8 digital inputs 8 digital outputs 4 analog inputs and 4 analog outputs The digital inputs can be connected by a switch contact type equipment while the analog inputs allow users to connect any industrial standard transmitter or sensor 0 20mA 4 20mA 0 5V and 0 10V The user can define each input acc...

Страница 6: ...ETY INSTRUCTIONS In this safety instructions the word device refers to FMGuard and all of its accessories Read Instructions Read all safety and operating instructions before operating the device Retain Instructions Save the safety and operating instructions for future references Heed Warnings Heed all warnings on the device and in the operating instructions Follow Instructions Follow all operating...

Страница 7: ...tection against voltage surges and built up static charges Lighting For added protection of the device during lighting storm or when it is left unattended and unused for long period of time disconnect it from the wall outlet and disconnect the antenna This will prevent damage to the device due to lighting and power line surges Power Lines An outside antenna system should not be located in the vici...

Страница 8: ...r A metal obeject falls to the device The device is damaged in some way Do not continue to use the device as this can cause a fire or electric shock Please observe the following when using the device Failure to do so can result in a fire or electric shock Do not use flammable sprays near the device Do not subject the device to strong impact Unboxing FMGuard FMGuard will be delivered to you in an e...

Страница 9: ...hysical Operating Voltage 24 to 36 VDC Battery On board 2Ah nominal Li Ion Battery Processor Cortex A5 32 bit ARM processor Cellular Modem GSM 850 900 1800 1900 MHz UMTS 800 850 900 1900 2100 MHz Operating Temperature Humidity 0 45 ºC 5 90 non condensing Physical Size W 160 2 x H 89 top x D 53 5 mm without terminal blocks and connectors Weight Approximately 465 g without accessories Mounting Indus...

Страница 10: ...iption 8 x digital solid state digital output Max 36 volt 1 5 A per channel Short circuit ESD Inductive kick back protected up to 20 mH User supplied power Configuration User defined output description Output Control Through SMS or locally On Off relay outputs through web browser and through Logic Expression Analog Input Analog Input Description 4 x analog inputs Range is 0 5 0 10VDC or 0 20 4 20 ...

Страница 11: ... devices f Acknowledgment SMS Alert Phone Groups a 48 Operation Numbers b 8 Authorized Numbers c 16 Escalation Numbers d 1 Forwarding Number e Accepts International Phone Number format and supports Auto Roaming Configurable SMS Message Digital Inputs Digital Outputs Alarm and Normal Analog Inputs Analog Outputs Crit low Low Normal High and Crit High Auto Health Check Programmable Daily or once a w...

Страница 12: ...ce See LCD Display for more information B TX and RX Modbus Transmit and Receive C S1 and S2 Shows the status and possible errors of the device See S1 and S2 function for more information D Reset Hold for 3 seconds to enter recovery mode Pressing reset will power reset the unit Table 3 2 FMGuard Front Parts Description A B C D ...

Страница 13: ...rd not yet implemented F L Out not yet implemented G Mic not yet implemented H SPKR not yet implemented I SIM Card Slot for SIM Card J PGM not yet implemented K Terminal Blocks Power Input and Output Terminals Table 3 3 FMGuard Bottom Parts Description E F G H I J K ...

Страница 14: ... slot for GSM M WiFi BT not yet implemented N USB External storage or slot for GSM modem O ETH RJ45 10 100Mbits P SER2 not yet implemented Q DIP not yet implemented R Terminal Blocks Power Input and Output Terminals Table 3 4 FMGuard Top Parts Description L M N O P Q R ...

Страница 15: ...an also be observed on the display Fast blinking green The device has been forced to recovery mode with the use of the system switch The application is not executing 500ms On 500ms Off green The device is on RUN mode 1 5s On 0 5 Off green The device is on RUN mode while charging the internal back up battery Fast Blinking red Runtime Error Alternating Fast Slow red The device lost its firmware This...

Страница 16: ...nected to a network 75ms On 75ms Off 75ms On 3s Off green GPRS session is active Flashing green GPRS on data transfer On green Voice session active On green all other LED s off System booting On yellow all other LED s off System booting on recovery mode On red all other LED s off System booting on monitor mode 10s Off 50ms On green all other LED s off Device is on low power mode Table 3 6 S2 LED P...

Страница 17: ...he power adapter termination blocks and Ethernet cable and have suitable GSM reception Follow carefully the instructions provided earlier in this manual on the safe use of this device and the instructions above on mounting FMGuard on to the Din Rail Step 2 Insert a valid 3G or 2G Micro SIM card into the SIM card socket slot the bottom of FMGuard Below shows the exact orientation of how the Micro S...

Страница 18: ...upplied as standard accessory is the unity gain antenna This antenna is suitable for most installation If the location has low GSM signal strength use high gain antenna or outdoor type Check with your distributor for suitable antenna alternatives Reset Button The button is located at the front side lower right of FMGuard this button is a combined reset diagnostic switch It is necessary to use a sm...

Страница 19: ... approximately 80 of initial capacity Lifetime of the Lithium coin cell in this state is 6 years External Li Ion Battery Optional External battery connection is possible on the terminal block connectors on the top side Jumpers located on the back side of the device is used to switch between the internal and external battery Note Only Lithium Ion batteries 3 7V nominal are allowed as external batte...

Страница 20: ...rmance and a shortened life expectancy Do not expose the device to water salt water or allow the battery to get wet Avoid strong impacts and shocks DIP SWITCH The DIP Switch located at the back of FMGuard is a mode selection switch for analog input and analog output Both analog input and analog output operate on two modes Voltage or Current mode The blue DIP switch is for the analog output while t...

Страница 21: ... 13 Y6 Digital output 6 14 Y7 Digital output 7 15 Y8 Digital output 8 4 16 S0 V S0 circuit isolated supply positive terminal 17 GND S0 digital input isolated ground negative terminal 18 X1 Digital input 1 S0 input 1 wake up ignition input 19 X2 Digital input 2 S0 input 2 20 X3 Digital input 3 S0 input 3 21 X4 Digital input 4 S0 input 4 5 22 X5 Digital input 5 23 X6 Digital input 6 24 X7 Digital in...

Страница 22: ...Digital input X1 X4 can be configured as S0 input IEC62053 31 Class A by supplying the S0 circuit through the S0 V and digital input GND 1 terminal pins and enabling the S0 interface through the user application When not supplied the inputs act as normal digital inputs The digital inputs X5 X8 are normal digital inputs To activate the normal digital inputs connect a positive voltage between the co...

Страница 23: ...nd user interaction with menus After loading FMGuard will show the Device ID IP address Subnet Mask Gateway Button to enable DHCP button to reset and lastly button to redirect on the main screen Once you close this screen you won t be able to access this setup anymore unless you restart your unit If you click DHCP a confirmation will pop up afterwards the FMGuard IP address will changed with accor...

Страница 24: ...ce the Digital Input or Output was triggered the box of the specific input or output will be filled with white color Analog input and analog output are represented by a bar graph depends on the value of analog the graph will go up high and go down low Clicking the icon of a bar graph will show a more detailed information if it is enabled on the configuration settings The toolbar at the top of the ...

Страница 25: ...h Data network connected while roaming Connected to a 2G network Call active Connected to a 3G network STATUS Tells if your SIM card is connected to the service provider SIGNAL LEVEL Measured value of signal in decibels NETWORK TYPE Type of network you are currently connected 2G or 3G PROVIDER PLMN mobile network code ...

Страница 26: ...address of the device SUBNET Depends on the connectivity requirements and network technology employed on the device GATEWAY The node in the network that uses IP protocol suite to serves as the forwarding host to other network when no other route specification matches the destination IP address of a packet ICON DESCRIPTION LAN OFF LAN ON LAN Connected ...

Страница 27: ...r device is connected to a gateway GATEWAY Server gateway IP address and port number NODE ID Serial number of the device INTERFACE Network connection type either ethernet or 3G ICON DESCRIPTION Gateway not enabled Gateway enabled Gateway connected ...

Страница 28: ...programming cable BATTERY STATUS BATTERY LEVEL Ranges from 1 5 where 5 is fully charged CHARGING Tells if the battery is currently charging RUN ON BATTERY Battery will act during power interruptions without the device booting EXTERNAL SUPPLY External supply that powers up the device during normal condition TEMPERATURE The current temperature inside the device ...

Страница 29: ...U as password To access the device settings press the time on the status bar for more than 1 seconds and release A dialog box asking for the admin password appears Take note that the password is case sensitive and that the keyboard default is to lower case letters The device settings can be used to configure some properties for the device Below are the settings you can change SET TIME set the date...

Страница 30: ...tput on the screen without logging in on the device and also the admin time out JUMPERS shows dialog for configuring virtual jumpers in the device LOG OUT to log out on the device CALIBRATION used to calibrate the contrast and accuracy of the LCD touchscreen ABOUT details about the device serial number system firmware runtime firmware model and device version ...

Страница 31: ... FMGuard provides the time stamping information Device ID The identity given by the user during the software configuration Input Terminal Address The terminal address is where exactly the alarm is connected to the FMGuard such as X1 X2 or AI1 and AI2 Input Description The user defined input description during the software configuration Commonly named after the device connected to the FMGuard Alarm...

Страница 32: ...ch or directly to a PC FMGuard is can be either STATIC or Dynamic Its default IP address is 192 168 1 10 Standalone Configuration Static IP An ethernet cable provided with the FMGuard unit is required to connect the FMGuard to a PC or laptop In order for the FMGuard and PC to connect to each other the PC must be manually set to a statis IP address that is within the same subnet as FMGuard Given th...

Страница 33: ...the IP address of the PC has been configured the user can set up the device using the PC browser The PC IP address must be in the same network range as the device Open any web browser application on your PC It can be Internet Explorer version 6 above Firefox Safari Netscape Google Chrome or any standard web browser At the address bar type in the IP address of FMGuard if you set the IP of FMGuard t...

Страница 34: ...fault user name and password for administrator is admin Guest user s username and password is guest Only the administrator has the right to change the password on the settings of user interface Follow through the various pages to setup the parameters according to the user s requirements ...

Страница 35: ...ide it The dashboard also shows the status of the external devices connected to the FMGuard via RS485 1 terminal Modbus It also shows the event logs located at the bottom of the page In a configured device the status of all input and output channels are displayed in this page Any change in the input and output will automatically updated live Digital Input X This table shows the tags under digital ...

Страница 36: ...thin the normal range High alarm when reading rises the preset High Alarm and Low alarm when reading falls to the preset Low Alarm Digital Output Y This field displays the digital output descriptions The status of the digital output displays either ON the contact of the digital output is closed OFF the contact of the digital output is open or Logic the digital output is controlled by logical expre...

Страница 37: ... alarm input has a set of variables for the user to enter Following is the description of each field that the user can identify and configure FMGuard has 8 digital inputs X1 X8 Input Description This field is for the user to provide meaningful name for the point to be monitored The description can be up to 40 characters long Open Status This field describes the state of the input when the contact ...

Страница 38: ...state is The status page will show the state of the input based on the state description configured Operation Group Check box to allow SMS to be sent to Operation group A F when digital input changes state Check the send emails if you want to receive notification via email Analog Input There are 4 analog input channels on FMGuard which can be interface to any industrial standard transmitter FMGuar...

Страница 39: ...e the raw value signal from the transmitter You can add or subtract constant value to the raw value and FMGuard will show you the computed value on the dashboard Set Points FMGuard has 4 setpoints for the analog input Critical Low Low High and Critical High Each setpoints are set to notify the users every time the signal passes or lowers the setpoints Note Set the Hysteresis to prevent the transmi...

Страница 40: ...form necessary action Remote Override When enabled the users with privilege will have the rights to turn ON and OFF digital output remotely via text Logic Expression Logical expression to turn ON or OFF an output The Logic expression has a built in calculator shown at the left for easy typing Logic Type Select the type of output when logic expression is true a ON Turn ON the output when logic expr...

Страница 41: ...forming the required action FMGuard replies to the sender with corresponding reply message Another way to control the digital output without going through the SMS is by clicking the output control section in the Dashboard Modbus Discrete Inputs FMGuard is capable on expanding its monitoring points via RS485 Modbus Modbus Discrete Input page will only appear on IO configuration if you add a device ...

Страница 42: ...RTU settings Please be reminded that FMGuard and any device integrated with it via Modbus should have the same RTU settings Baudrate the rate of the data transferred through Modbus Parity type of check bit used to detect error on data transmission Data Bits Size of the data Stop Bit basic error check to detect baud rate or byte length 2 Click on Modbus Devices 3 After setting up the parameters of ...

Страница 43: ...ing The tag address on PicoboxDAQ for FMGuard are the last 3 numbers of the address Tag Type There are 4 type of tag address on FMGuard Modbus Coil Modbus Discrete Input Modbus Input Register and Modbus Holding Register If a tag address starts with 0x it is identified as Modbus coil If a tag address starts with 1x it is identified as Modbus discrete input If a tag address starts with 3x it is iden...

Страница 44: ...g at the IO configuration and dashboard 7 Enable polling for each device 8 Click the checkbox at the RTU settings to enable the Modbus function 9 Configure the tags on IO Configuration Depend on tag type the tag will either go to Modbus Coil Modbus Discrete Input Modbus Input Register and Modbus Holding Register page ...

Страница 45: ...s activated normal to high vice versa or normal to low vice versa Up to 48 mobile phone numbers can be assigned on this group Phone numbers of up to 15 digits and are valid formats Example 09123456789 659123456789 Escalation Numbers When alarm is triggered escalation group timers are activated If none of the operation numbers who received the SMS prompt of FMGuard response an acknowledgement reply...

Страница 46: ...ow which location the ZSMS alert came from even if there was a change in the device s SIM card number LAN Configuration This setting is self explanatory Care is to be exercised in setting IP address and subnet mask values Incorrect IP address subnet mask setting will render FMGuard inaccessible from the network Invalid IP Subnet range will also cause FMGuard inaccessible to the network FMGuard do ...

Страница 47: ...d when user reply with an acknowledge command Repeat Interval SMS repeat duration is between 2 60 mins To cancel repeated SMS any mobile phone from the operation or forward group must acknowledge the alarm of FMGuard by replying ACK This command is non case sensitive ack Ack ACK are all valid strings FMGuard upon receipt of the acknowledge command will stop sending further SMS to this alarm Send S...

Страница 48: ...ber of strata Email Settings Authentication Tick this box if your email needed authentication TLS Tick this box if your email is encrypted Server Outgoing server of your email provider Port The port to use default for SMTP without encryption is port 25 584 and 2525 are also used For encrypted TLS usually port 587 Username The log in credential to use when authenticating Password The password crede...

Страница 49: ...rd Date and time information is also present at the SMS notification when alarm is triggered Reporting FMGuard can push reports to remote servers Each report contains current status information of each tags recorded on the unit The report format is in easy to parse text format the format is available on request from Linkwise Technology FMGuard has 4 formats of report CSV URL encoded Form JSON and ...

Страница 50: ...50 P a g e User Authentication not yet implemented Used to change the username and password Upto 5 users can be register Delete Outbox Content Delete the outbox messages of email and SMS ...

Страница 51: ...age has all of the events occur on FMGuard It has maximum of 500 entries first in first out It has search function for easy access Logs can be saved manually by clicking either the CSV button and XML button format depends on the button ...

Страница 52: ...ion is taken by it Any unauthorized mobile phones that tried to query a status or do a set command will be disregard and no action will be taken Phone Groups Command An authorized person can perform query and perform commands on Operation Forward and Authorizer mobile phone numbers stored in the unit s memory Description Format Sample Command Remarks Rights Operation Authorized Adding or replacing...

Страница 53: ...name RD X1 RD X Door Access n digital input 1 8 di_name digital input description RD AI RD AI RD AI n RD AI ai_name RD AI1 RD AI Temperature n analog input 1 4 ai_name analog input description Output Control SET Y n ON SET Y do_name ON SET Y1 ON SET Y Light ON n digital output 1 8 do_name digital output description SET Y n OFF SET Y do_name OFF SET Y1 OFF SET Y Light OFF n digital output 1 8 do_na...

Страница 54: ...ai_name analog input description SET Y n Name do_name SET Y1 Name Light n digital output 1 to 8 do_name digital output description SET AO n Name ao_name SET AO1 Name Servo Motor n analog output 1 to 4 ao_name analog output description Set Change Digital Input Status SET X n OS openstate_name SET X di_name OS openstate_name SET Y1 OS OPEN SET Y Light OS OPEN n digital output 1 to 8 do_name digital ...

Страница 55: ... 1 to 8 analog input alarm ACK AI n ACK AI1 n analog input 1 to 4 Acknowledge specific digital output alarm ACk Y n ACK Y1 n digital output 1 to 8 Acknowledge specific digital output alarm ACK AO n ACK AO1 n analog output 1 to 4 Remote SMS command Benefits With the remote command functionality above it saves time and effort o Re assigning of operation personnel a change of mobile phone number is a...

Отзывы: