7 Putting into Service and Test
7.1 Test the Communication between Controller and PC
1. Connect the serial interface of the PC to the controller (X5), see Chap. 1.2.
2. Connect the supply voltage PWR to the controller (X9). The LED should light green.
3. Set the Remote/Local switch to REMOTE.
4. Switch on the PC.
5. Install MiniLog-Comm program package delivered with the controller.
6. Select the required settings in MiniLog-Comm, menu item
Options/Interface
parameters
, and save them: Active COM, transmission protocol and baud rate.
The baud rate in the controller can be changed by clicking on
A
d
v
a
n
c
e
d
>
>
and can be
saved by
Set!
.
Baud rates MCC-1
can be selected in menu item
Options/Interface
parameters
or by programming instruction
9600
38400
14400
57600
19200
115200
28800
Factory settings
Baud rate programming instruction
:
IC
p
S
nnn
IC
Code: programming a baud rate
p
Port number 1
S
Write (Schreiben)
nnn
Enter baud rate
Data format for transmission
:
No Parity
1 Stopbit
8 Bit ASCII-Code
57600 Baud
All
instruction strings
must have the following format:
STX Data ETX
Control characters: see ASCII table
The programming instructions are listed in the MiniLog programming manual.
Содержание MCC-1
Страница 13: ...Manual MCC 1 MA 1249 A009 EN 12 1 6 Declaration of Incorporation...
Страница 26: ...phytron 25 MA 1249 A009 EN 1 Fig 12 Wall mounting MCC 1 dimensions Fig 13 Rail mounting MCC 1 dimensions...
Страница 45: ...Manual MCC 1 MA 1249 A009 EN 44 Fig 38 Enable Connector wiring...
Страница 54: ...Phytron GmbH Industriestra e 12 82194 Gr benzell T 49 8142 503 0 F 49 8142 503 190 www phytron eu...