Manual MCC-1
MA 1249-A009 EN
22
5.2 Electrical Data
Technical Characteristics
Suppy voltage
Unregulated filtered DC voltage
Admissible voltage range for
Controller and motor: 24 to 48 V
DC
(X9)
Limit switches and outputs: 24 V
DC
( X4)
Reinforced or double insulation between mains and
secondary circuit is required.
Stepper motor
Two-phase stepper motors in 4, 6 or 8 lead wiring scheme
at X8.
Winding resistance between 0.1 and 10 Ohm
Winding inductance 0.5 to 10 mH per phase
Phase current
up to 3.5 A
Peak
Step resolution
1/1, 1/2, 1/4, 1/5, 1/8, 1/10, 1/20 of a full step,
enhanced setting range up to 1/256 step for smoother motor
run.
Max. run frequency
40 kHz for full step, 20 kHz for half step
Interfaces
RS 485, RS 232 or USB (X5)
Connectors
1 analog input (X1)
2 Limit switch inputs (X2)
8 digital inputs or outputs (X3)
1 Encoder (incremental or SSI) (X6)
Fuse
6.3 A fast
Flash memory
10 000 write cycles under normal operating conditions
Ambient temperature
Operation: 5 to 50 °C
Storage: -10 to 60 °C
Transport: -10 to 60 °C
Temperature behaviour
Heating curve see appendix B