6.2 Electrical Installation
Connectors - Overview
Connector Number
of poles
Phoenix connector type
Phoenix mating
connector
Material
number
(mating
connector)
X1 / X2
2 x 5
MCDN 1,5/5-G1-3,5 P26THR FMC 1,5/5-ST-3,5
#10006540
X3 / X6
2 x 8
MCDN 1,5/8-G1-3,5 P26THR FMC 1,5/8-ST-3,5
#10005881
X4
2
MC 1,5/2-G-3,5 THT
FMC 1,5/2-ST-3,5
#10007077
X8
4
IC 2,5/4-G-5,08
IC 2,5/4-ST-5,08
#10005390
X9
2
MSTB 2,5/2-GF-5,08
MSTB 2,5/2-STF-5,08 #02005267
X10
5
FMC 1,5/5-G-3,5
FMC 1,5/5-ST-3,5
#10006540
6.3 Connection of the Power Supply
6.3.1 X4 Power Supply I/O
Fig. 14: X4 Connector Supply I/O
DANGER
Danger of electric arcing!
Do not
plug or unplug any connector when powered!
The I/O supply voltage is connected to the X4 connector and supplies outputs and limit
switches.
Nominal value: 24 V
DC
I/O
Permissible range: 19.2 to 30 V
DC
The power requirement is dependent on the connected outputs and limit switches, 3 A are
allowed.