Jumper
PHYTEC Meßtechnik GmbH 1999 L-356e_2
25
S3
switch 1
Boostrap mode
(on)
normal Program
(off)
Execution Mode
S3
switch 2
switch 3
five /CS-Signals (off)
available at port (off)
P6
Number of /CS-Signals at port P6
(0, 2 or 3)
S3
switch 4
switch 5
two Segment Address
Lines (off) (A17, A16) at port (off)
P4 available
Number of Segment Address
Lines at port P4 (0, 4 or 8)
S3
switch 6
switch 7
switch 8
System Clock (off)
Speed = XT1 * 4
(off)
(off)
Prescaler to generate the System
Clock Speed from XT1 (*1, *2,
*3 or *5)
Table 4:
Jumper Setting
4.1
Program Storage JP1
At the time of delivery, Jumper JP1 is preconnected between pins
1+2. This default configuration means that the program stored in the
external program memory is executed after Reset. In order to allow
the execution of a specific controller’s internal program memory,
jumper JP1 must be closed at 2+3.
Code-Access
JP1
external Program Storage
1+2*
internal Program Storage
2+3