Jumper
PHYTEC Meßtechnik GmbH 1999 L-356e_2
29
4.8
Configuration of ports P4.4 – P4.7 JP11, JP12
The kitCON-161CS/JC/JI can be equipped with different C161
derivatives. These derivatives vary in number and type of the
interfaces available at ports P4.4 – P4.7. With jumpers JP11 and JP12
these alternate functions of port P4 can be enabled on the
kitCON-161CS/JC/JI. The Table below shows the pinout of ports
P4.4 – P4.7. If no alternate function is given the port serves only as
digital I/O or address line.
Controller
P4.4
P4.5
P4.6
P4.7
C161CI
-
CAN_RXD
CAN_TXD
-
C161JI
SDL_RXD
-
-
SDL_TXD
C161JC
SDL_RXD
CAN1_RXD
CAN1_TXD
SDL_TXD
In order to utilize the interfaces jumpers JP11 and JP12 must be
configured as shown below:
C161CS
JP11
JP12
P4.4 as CAN1_RxD
1+2
P4.5 as CAN_RxD
5+6
P4.6 as CAN_TxD
3+5
P4.7 as CAN1_TxD
2+4
C161JI
JP11
JP12
P4.4 as SDL_RxD
2+4
P4.7 as SDL_TxD
4+6
C161JC
JP11
JP12
P4.4 as SDL_RxD
2+4
P4.5 as CAN_RxD
5+6
P4.6 as CAN_TxD
3+5
P4.7 as SDL_TxD
4+6
NOTE:
Other configurations of jumpers JP11 and JP12 are reserved for
future functions. If ports P4.4 – P4.7 are used as digital I/O or
address line jumpers JP11 and JP12 must remain open..
Содержание kitCON-161CS
Страница 28: ...kitCON 161CS JC JI 22 PHYTEC Me technik GmbH 1999 L 356e_2...
Страница 44: ...kitCON 161CS JC JI 38 PHYTEC Me technik GmbH 1999 L 356e_2...
Страница 54: ...kitCON 161CS JC JI 48 PHYTEC Me technik GmbH 1999 L 356e_2...
Страница 58: ...kitCON 161CS JC JI 52 PHYTEC Me technik GmbH 1999 L 356e_2...
Страница 62: ...Published by PHYTEC Me technik GmbH 1999 Ordering No L 356e_2 Printed in Germany...