VL PPC 3000
3386_en_C
PHOENIX CONTACT
11/16
8
Maintenance
8.1
Service panel
The service panel on the top of the VL PPC 3000 can be
removed to access the data storage and other components.
Several components within the IPC can be removed or
replaced.
8.2
CFast
®
card
The CFast card is secured into the slot with a retaining
Card installation
1.
Open the service door (1).
2.
Align the connections on the card with the CFast slot (2)
inside the VL PPC 3000. Push the card into the slot until
secured by the internal catch mechanism.
3.
Close the service door before applying power to the
unit.
Card removal
1.
Open the service door (1).
2.
Push the card into the slot and then release it, allowing
the internal catch mechanism to release the card.
3.
Close the service door before applying power to the
unit.
8.3
HDD/SSD
Data storage can be via a rotating hard-disk drive (HDD) or
solid-state drive (SSD) (see Figure 7).
Tray removal
1.
Open the service door (1).
2.
Use a screwdriver to rotate the release knob (3)
counterclockwise until loose.
3.
Grasp the knob (3) and pull to swing the lever (4) out.
4.
Use the lever to pull the tray (5) out of the chassis.
Figure 7
Service panel and component access
NOTE: Electrostatic discharge!
The device contains components that can be
damaged or destroyed by electrostatic discharge.
When handling the device, observe the neces-
sary safety precautions against electrostatic dis-
charge (ESD), in accordance with EN 61340-5-1
and EN 61340-5-2.
X10:COM
ERR
OR
RU
N
HDD
PWR
X7:USB
X6:USB
X5:USB
X4:USB
X9:DP++
X3:ETH
X2:ETH
X1:
PWR 24VDC
③
④
②
①
⑤