Mounting and installation
108413_en_06
PHOENIX CONTACT
25 / 52
3.3
Connecting to the network
The network can be connected (depending on the device) via RJ45 ports using twisted pair
cables (IEEE 802.3i/u/ab).
3.3.1
Using RJ45 Ethernet connectors
Connecting RJ45 Ethernet connectors
•
Observe the correct connector coding (see also
).
•
Only use twisted pair cables with an impedance of 100
and a length of maximum
100 m (per segment).
•
Only use shielded twisted pair cables and corresponding shielded RJ45 connectors. In
-
sert the Ethernet cable with the RJ45 connector into a port of the twisted pair interface
(network interface 1 or 2), until the connector engages with a click.
NOTE:
Connect the network connections (Ethernet) of the device to LAN installations on
-
ly. Some telecommunications connections also use RJ45 connections; these must not be
connected to the RJ45 connections of the device.
For operation with 1000 Mbps (Gigabit), the following applies: Cables with four twisted
pairs (eight wires) that meet the requirements of CAT5e as a minimum must be used.
Table 3
-
2
Pin assignment of the RJ45 connectors
Pin number
10Base-T (10 Mbps/s)
100Base-TX (100 Mbps/s)
1000Base-T (1000 Mbps/s)
1
TD+ (transmit)
TD+ (transmit)
BI_DA+ (bidirectional)
2
TD- (transmit)
TD- (transmit)
BI_DA- (bidirectional)
3
RD+ (receive)
RD+ (receive)
BI_DB+ (bidirectional)
4
–
–
BI_DB- (bidirectional)
5
–
–
BI_DC+ (bidirectional)
6
RD- (receive)
RD- (receive)
BI_DC- (bidirectional)
7
–
–
BI_DD+ (bidirectional)
8
–
–
BI_DD- (bidirectional)
Содержание 1153079
Страница 1: ...User manual UM EN FL MGUARD 1000 FL MGUARD 1000 Installation and startup...
Страница 10: ...FL MGUARD 1000 product family 10 52 PHOENIX CONTACT 108413_en_06...
Страница 28: ...FL MGUARD 1000 product family 28 52 PHOENIX CONTACT 108413_en_06...
Страница 50: ...FL MGUARD 1000 product family 50 52 PHOENIX CONTACT 108413_en_06...
Страница 53: ......