25
2.4
Motor Power Output
2.4.1
Motor Power Output Cable Fabrication
Motor Power Output Cable has two sides: drive side and motor side. This manual only mention the
fabrication of drive side. And the motor side fabrication differs from different motors. If the motor
is manufactured by Phase Motion Control, our Prefabricated Motor Power Output Cables are
recommended. Refer to: Appendix: Prefabricated Cable——5.1 Motor Power Output cable for
more details.
Step 1: Cable Selection
AxN Size5 drive must use a 4 wire cable with shield as its motor power output cable. Refer to the
table below to select the appropriate cable:
AxN Size5
Current (A rms)
Recommended
Gauge (mm
2
)
Recommended
Gauge (AWG)
AxN 90.150.4
90
21.15
4
AxN 110.200.4
110
26.67
3
Step 2: Cable Length Measurement
Measure the distance between drive and motor then determine the suitable cable length.
Step 3: Strip the Cable Coat
Strip the outside coat of the DC power supply cable for 160mm and reveal the inside shield.
Step 4: Make the Grounding Shield
Leave 65mm Shield as the grounding shield and turn it to the outside of the coat. Then, weld a wire
on the shield as the drainage line.
Содержание AxN series
Страница 2: ......
Страница 7: ...5 1 3 Overall Dimensions...
Страница 21: ...19 area contact against the cable support so that they can together be grounded through drive housing...
Страница 32: ...30...
Страница 37: ...35 When the drive is ready N O connects Com and N C disconnects Com illustrated as below...
Страница 50: ...48 Connection diagram Note Only the first and the last CAN node device should use a 120 terminal resistor...