33
STO Function
Normal version AxN Series Drive does not have the STO function. If you want to use the STO
function, you must order a STO version AxN Series Drive. There are 2 pins which are related to the
STO function, 24V_SAF_H and 24V_SAF_L. If you cut either of these pins’ power, STO will be
activated and the motor will stop. Normal version AxN Series Drive has already internally short cut
Pin 24V_AUX, 24_SAF_H and 24V_SAF_L, so that STO function is disabled.
Step 3: Connect the Cable to Terminal
Insert DC+ wire into terminal 24V_AUX and insert DC- wire into PE_AUX, then use a screwdriver to
tight the screws on the terminals.
Step 4: Insert Terminal into Port
Insert the terminal along with the cable into Auxiliary Power Supply Port (AUX_Power).
Содержание AxN series
Страница 2: ......
Страница 7: ...5 1 3 Overall Dimensions...
Страница 21: ...19 area contact against the cable support so that they can together be grounded through drive housing...
Страница 32: ...30...
Страница 37: ...35 When the drive is ready N O connects Com and N C disconnects Com illustrated as below...
Страница 50: ...48 Connection diagram Note Only the first and the last CAN node device should use a 120 terminal resistor...