Mixing Pump RITMO XL FU 230V Overview – Operation
Maintenance
2019-12-11
53
41 Maintenance
41.1 Safety
Personnel
The maintenance works described here can be carried out
by the operator, unless marked otherwise.
Some maintenance work must only be carried out by
specially trained technical personnel or exclusively by the
manufacturer.
Work on the electrical system must, in principle, be carried
out only by electricians.
Basic information
WARNING!
Risk of injury due to improperly carried out
maintenance work!
Improper maintenance can lead to severe
injuries or considerable property damage.
Therefore:
Ensure order and safety at the assembly
site! Loose, stacked components or
components lying about can cause
accidents.
If components were removed, ensure proper
assembly, put back all fastening elements
and observe torque indications for screws.
41.2 Remove connection cable
Electrical system
Fig. 93: Remove connection cable
DANGER!
Danger of death from electric current!
There is danger to life if you come in contact with live
parts. Activated electrical components can carry out
uncontrolled movements and cause serious injuries.
Therefore:
Switch off the energy supply before starting any work
and secure against restarting.
Disconnect the power supply by removing the
connection cable