Mixing Pump RITMO XL FU 230V Overview – Operation
Measures against danger of frost
52
2019-12-11
40.1 Blowing water fitting dry
Fig. 91: Connecting air hose
1. Connect air flange with Geka coupling and EWO coupling to
compressed air connection (1) and water connection (2).
Fig. 92: Blowing water fitting dry
2. Set main switch (3) to position "I".
3. Press the green pushbutton (4) Control voltage "ON".
4. Activate air compressor (5).
5. Press water upstream button (6).
6. The water is now blown with compressed air out of the fitting (for
approx 15 seconds).
7. Open all water valves and blow out with compressed air again.
8. Switch off compressor (5).
9. Set reverse switch (3) to position "0".
1
2
3
4
5
6