![PFT RITMO XL FU Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/pft/ritmo-xl-fu/ritmo-xl-fu_operating-instructions-manual_1535721044.webp)
Mixing Pump RITMO XL FU 230V Overview – Operation
Removal of blockages in the hose
44
2019-12-11
37.8 Earlier damage to the mortar hose
NOTE!
If in the event of a machine fault by material clogging the
pressure in the mortar hose exceeds 60 bar, even only
temporarily,
replacement
of
the
mortar
hose
is
recommended as there might be damage in the hose that is
not externally visible.
38 Removal of blockages in the hose
DANGER!
Danger from discharged material!
Never loosen the hose couplings as long as the pressure
head is reduced! Material to be conveyed can be
discharged under pressure and cause injuries particularly to
the eyes.
Persons commissioned with the cleaning of clogged hoses
have to wear personal protective equipment (protective
goggles, gloves) for safety reasons, and to position
themselves in such a way that they cannot be hit by
discharged material. Other persons have to clear the area.
38.1 Change the direction of rotation of the mixing pump motor in case
of blockages in the hose 50Hz
Fig. 68: Change direction of rotation
50Hz
1. Turn the selector switch for the air compressor (1) to position ”0“
2. Turn the main switch (2) to position "0".
3. Press the green push button (3) control voltage “ON”.
4. Turn selector switch of the pump motor (4) briefly anti-clockwise,
until the pressure at the mortar pressure gauge has dropped to “0
bar”.
2
3
1
4