Mixing Pump RITMO XL FU 230V Overview – Operation
Preparation
2019-12-11
27
Fig. 30: Locking roller
1. Lock the locking roller before operating the machine.
2. Place the machine securely on an even surface and lock it
against inadvertent movements:
Do not tilt or move the machine.
Set the machine up in such a way that it cannot be affected by
falling objects.
The controls must be accessible freely.
24.1 Connection of power supply
Fig. 31: Connecting power 230V 50Hz
1. Connect the machine only to a 230V AC power supply line.
DANGER!
Danger to life from electric current!
The connecting cable must be secured correctly:
Connect the machine only to a power source with
permissible FI circuit breaker (30mA) RCD
(Residual Current operated Device) Type B,
sensitive to all current types, for the operation of
frequency converters
24.2 Connection of power supply 230V 3Ph. 60Hz
Fig. 32: Connecting power 230V 60Hz
1. Connect the machine only to a 230V AC power supply line.
DANGER!
Danger of death from electric current!
The connection line has to be fused properly:
Connect the machine only to a power source with
permissible RCCB (30 mA) RCD (residual current
operated device) type A.
24.3 Check the individual connectors
2
1
Fig. 33: Power connections
Check connection of air compressor (1).
Check connection of delivery hood (2).
WARNING!
Danger to life from rotating parts!
Improper operation may lead to serious damage to
persons or property.
The respective drive (motors) must be operated
only with the control cabinet of the machine.