Mixing Pump RITMO XL FU 230V Overview – Operation
Work on troubleshooting
2019-12-11
39
3
6
4
5
Fig. 66: Power failure
NOTE!
The RITMO XL is equipped with a restart interlock.
In case of a power cut, the system has to be started
as follows.
5. Turn main switch (3) to position "I".
6. Switch on the air compressor (4).
7. Press the green push button (5) control voltage “ON”.
8. Switch on the machine, turn the selector switch of the pump motor
(6) clockwise.
9. The RITMO XL starts again as soon as the air tap at the spray
gun is opened again.
NOTE!
In case of a longer power cut, the RITMO XL and the
material hoses have to be cleaned immediately.
37 Work on troubleshooting
37.1 Reaction in the event of faults
The following strictly applies:
1. In the event of faults presenting immediate danger to
persons or property, activate the emergency off function
immediately (switch off main switch).
2. Determine cause for fault.
3. If the rectification of faults requires works in the danger
zone, switch off the system and secure against restarting.
4. Inform the manager on site immediately about the fault.
5. Depending on the type of fault commission authorised
skilled personnel or rectify the fault yourself.
NOTE!
The following fault table gives information on
who is authorised to rectify the fault.