PFT continuous mixer HM 2002 Overview - Operation - Spare parts lists
Connecting the water supply
2017-03-14
23
21 Connecting the water supply
21.1 Clean the strainer screen
Fig. 20: Water inlet screen
1. Check whether the strainer screen in the water inlet (1) is clean.
2. If necessary, remove the strainer screen from the water inlet
and clean it.
Strainer screen with Geka coupling:
Article number 20152000
3. Remove the brass screen cup (2) from the pressure reducer.
4. Check whether the strainer screen in the pressure reducer (3) is
clean.
Screen for pressure reducer: Article number 20156000
5. Screw the brass cup (2) back.
21.2 Connecting the water hose
1
Fig. 21: Connecting the water hose
1. Close the water drain valves (1).
2. Clean and vent the water hose (2) of the water supply network
and connect it to the water inlet (3).
3. Open the water tap form the water supply line.
4. Open the water extraction valve (4).
5. As soon as water comes out at the water extraction valve (4),
close it again.
NOTE!
Use only clean water free of solids. The minimum
pressure is 2.5 bar when the machine is running.
1
3
2
3
2
4