PFT continuous mixer HM 2002 Overview - Operation - Spare parts lists
Maintenance work
2017-03-14
39
38.2 Lubrication
1
Fig. 50: Lubrication
Lubricate the bearings for the dosing shaft at the lubricating nipple
(1) once in six months.
Implementation by operator.
38.3 Changing the V-belt
Fig. 51: V-belt
1. Loosen the four screws (1) and remove the cover
hood (2).
2. Loosen the counter nuts (3) and screws (4).
3. The V-belt is tensioned by the dead weight of the
gear motor.
4. The indentation depth should not be more than one
centimetre.
4
3
2
1
1 cm