PFT continuous mixer HM 2002 Overview - Operation - Spare parts lists
Measures in case of risk of frost
2017-03-14
35
35.9 Cleaning the dosing shaft
2
1
Fig. 43: Cleaning the dosing shaft
1. Loosen the nuts of the screw (1).
2. Remove the dosing shaft (2) and clean it.
3. Reinsert the cleaned dosing shaft and secure with nuts and the
screw.
4. Set the protective grille and secure it.
35.10 Setting the mixing shaft
2
1
Fig. 44: Setting the mixing shaft
1. Assemble clean and dry parts only.
2. Keep the quick closures at the mixing tube clean.
3. Move the cleaned mixing shaft into the mixing tube and connect
with dosing shaft.
4. Fasten the star plate (2) using the ring nut (1).
36 Measures in case of risk of frost
ATTENTION!
Damage by frost!
Water that expands inside the machine during frost
can cause severe damage.
– The following steps are to be carried out if the
machine stands still in case of risk of frost.