PFT continuous mixer HM 2002 Overview - Operation - Spare parts lists
Measures to be taken in case of water outage
2017-03-14
31
Mortar flow
ceases
Bad mixture in mixing tube
Add more water
Operator
Material is clumped and narrows
the water inlet
Remove the material and clean the
water inlet
Operator
Material in material container has
become wet
Remove the wet material and dry
the material container
Operator
Mixing shaft defective
Replace the mixing shaft
Operator
Mortar flow
‘thick-thin’
Too little water
Increase the water quantity by 10%
for approx. ½ minute and then turn
down slowly
Operator
Mixing shaft defective; no original
PFT agitator
Replace the mixing shaft with
original PFT agitator
Operator
Pressure reducer set incorrectly or
defective
Adjust or replace pressure reducer
Service engineer
33
Measures to be taken in case of water outage
NOTE!
Water can be supplied to the machine from a
container by means of a booster pump (article
number
00493686
) (see page 24 point
22.3
)
34 Cleaning
34.1 Secure against restarting
DANGER!
Danger to life from unauthorised restarting!
When working with the machine there is the risk
that the energy supply is switched on without
authorisation. This poses a danger to life for the
persons in danger area.
– Switch off all energy supplies before starting
any work and secure against restarting.