PFT continuous mixer HM 2002 Overview - Operation - Spare parts lists
Structure of HM 2002
12
2017-03-14
10.2 Water fitting
1
8
7
6
3
5
4
3
2
Fig. 6: Water fitting
1. Water connection to mixing tube.
2. Needle valve to adjust the water quantity.
3. Water drain valve (in case of risk of frost).
4. Solenoid valve.
5. Pressure reducer.
6. Water extraction.
7. Water extraction valve.
8. Water inlet from water supply or water pump.
10.3 Retrofit kit for water flow meter 100 - 1,000 l/h for HM 2002
1
2
3
4
5
Fig. 7: Retrofit kit for water flow meter
1. Water connection to mixing tube.
2. Needle valve to adjust the water quantity.
3. Attachment to material container.
4. Water flow meter 100-1000 l/h.
5. Connection to angular distributor with ball valve.