3 TECHNICAL SPECIFICATIONS
Rated operating voltage..................................................................................... 12±1.2VDC
Consumption current
......................................................................................... max 0.15 A
Power consumption ................................................................................................ max 2 W
Number of controlled entrance points ................................................................................ 1
Number of RC inputs ......................................................................................................... 1
Proximity card types ...................................................................................
HID
,
EM-Marine
Card reading distance at the rated operating voltage for different card types:
for HID cards ................................................................................................ min 5 cm
for EM-Marine cards...................................................................................... min 8 cm
Card reading distance with lock controller installed on metal surface:
for HID cards ................................................................................................. min 4 cm
for EM-Marine cards...................................................................................... min 7 cm
Lock controller connection interface standard....................................
Ethernet
(IEEE 802.3)
Number of users (proximity cards)................................... from 10,000 to 50,000 (see Note)
Number of log events
1
............................................... from 230,000 to 870,000 (see Note)
Note:
Possible options for allocating memory (see Appendix 2, Clause 3.4):
50,000 cards and 230,000 events – set by default,
40,000 cards and 390,000 events,
30,000 cards and 550,000 events,
20,000 cards and 710,000 events,
10,000 cards and 870,000 events.
Number of additional outputs
2
........................................................................................... 1
Mean lifetime ........................................................................................................... 8 years
Electric shock protection class............................................ III
under GOST R IEC 730-1-94
Housing protection class ................................................................... IP54 under EN 60529
Lock controller dimensions (without cable) ...................................................145×50×20 mm
Lock controller weight ........................................................................................ max 0.3 kg
Note:
Initially lock controller features: IP-address and MAC-address, stated in the product
certificate and at the inner side of the product housing; subnet mask: 255.0.0.0;
gateway IP-address: 0.0.0.0.
1
If log event is overloaded, new events start replacing the old ones (events are deleted in
blocks of 256).
2
Additional output configuration variants are described in Section 5.4.
4
Содержание CL-05.2
Страница 1: ...Lock Controller CL 05 2 OPERATION MANUAL ...
Страница 2: ...Lock Controller CL 05 2 Operation Manual ...
Страница 15: ...Operation Manual Figure 3 Controller connection scheme 14 ...
Страница 24: ...CL 05 2 Lock Controller Figure 5 Controller connection scheme through PoE splitter 23 ...
Страница 40: ......
Страница 42: ...www perco com ...