Operation Manual
5.4 Signal parameters of the additional output
Controller has one additional output (brown cable), which, depending on configuration, can
be used as a
Fire Alarm
input (Section 5.4.1)
,
as additional output (Section 5.4.2) or as a
synchronization channel at simultaneous operation of two controllers (Section 5.4.3).
This output is designed as a transistor n-p-n collector. In order to operate as an input, it is
connected to the power line +3.3 V through resistor with 4.7 kOhm resistance.
Choose additional output use variant in
PERCo-Web
Network Software
.
In order to set the
output operation mode, set the value according to Table 1 in
“Type”
parameter of the
“Additional
output”
controller resource.
Table 1. Output configuration in network Software
“Type” parameter value of the “Additional
output” controller resource
Output operation mode
“Fire Alarm”
“Fire Alarm”
input for emergency unlocking
device (Section 5.4.1)
“Standard”,
“Alarm generator”,
“Security and fire alarm”
Control output for additional equipment
(Section 5.4.2)
“Synchronizing”
Clock bus of two controllers simultaneous
operation (Section 5.4.3)
5.4.1 “Fire Alarm input”
In
“Fire Alarm
input”
mode the additional output is used for connecting emergency
unlocking device (“
Fire Alarm”)
. Connection scheme is given on Fig. 3.
Normally open relay contact or a scheme with open collector output can serve as a control
element. Input signal parameters are the same as stated for
Door
and
DU
inputs
(Section 5.3).
Sending control signal from (“
Fire Alarm”)
emergency unlocking device, connected to the
controller on the input, OD gets unlocked and stays in that condition until signal removing.
Indication block green passage grant indicator is ON. All control commands are ignored.
5.4.2 Output
In
“Output”
mode the additional output can be used for:
external light and sound (Alarm) indicator connection,
signal transfer to the central observation board,
other additional equipment connection.
Connection scheme is given on Fig. 3.
Output signal parameters:
maximum voltage DC ................................................................................. max 12
V
maximum current ..................................................................................... max 0.25
A
5.4.3 Synchronization
In
“Synchronization”
mode the output is used for synchronization of the simultaneous
operation of two controllers when two-sided entrance point is to be arranged. In this mode
controller outputs are connected between each other. This allows avoiding
OD Breaking
event registration when making the passage in direction, opposite to the one, in which the
controller is installed. Connection scheme is given on Fig. 4. In this case other equipment
connection to the additional outputs is not allowed.
8
Содержание CL-05.2
Страница 1: ...Lock Controller CL 05 2 OPERATION MANUAL ...
Страница 2: ...Lock Controller CL 05 2 Operation Manual ...
Страница 15: ...Operation Manual Figure 3 Controller connection scheme 14 ...
Страница 24: ...CL 05 2 Lock Controller Figure 5 Controller connection scheme through PoE splitter 23 ...
Страница 40: ......
Страница 42: ...www perco com ...