2
0
2
0
-0
3
8
Product Description
Front Panel
Figure 2.3
Front panel overview
WCS read head: LED status indicator and rotary coding switch
Power/State:
The "Power/State" LED lights up green: voltage supply is present.
State:
The "State" LED is green: Data is being exchanged with the WCS read heads. The four "Error
No/Select ID" LEDs are used to display the number of the currently polled WCS read head.
The "State" LED lights up red: The interface module has detected an error or a warning. The
interface module displays the binary-coded error and/or warning number via the "Error
No/Select ID" LEDs.
Error No/Select ID
Read head
address
8
4
2
1
0
0
0
1
0
0
0
1
0
1
0
1
0
0
2
1
0
0
0
3
Table 2.1
Display via the four "ErrorNo/Select ID" LEDs when the "State" LED lights up green
Error (No. 1...5):
Switch the interface module off and back on. If the error occurs
again, the module must be replaced.
Warning (No. 6...15):
The warning provides information. The interface module displays
the warning for one minute and then resets automatically.
Po
w
e
r
/Sta
te
1
2
4
8
S4
S5
Sta
te
WCS-PNG410 Modul
AB
C
D
E
F0
123
4
5
6
7
89
AB
C
D
E
F
01234
5
6
7
89
Sta
te
Po
w
e
r
L
in
k
/A
c
t.
P1
L
in
k
/A
c
t.
P2
PROFINET