Connecting the WCS Read Head
If you connect several WCS read heads to one interface module, the WCS read heads must
have different addresses. This will allow the programmable logic controller to allocate the data
to the correct WCS read heads. If you connect only one WCS read head to an interface mod-
ule, this WCS read head always receives the address 0. You can connect up to four WCS read
heads to an interface module via an RS-485 cable. Each WCS read head is supplied with the
default address of 0. Details of how to change the address of the WCS read head can be found
in the configuration instructions for the WCS read head.
The number of connected read heads and their operating mode is configured in the hardware
project planning. Use the GSDML file for the hardware project planning. This file can be down-
loaded from our website: http://www.pepperl-fuchs.com.
Rotary Coding Switch S4
Rotary switch S4 has no function. Make sure that the rotary switch is in switch position 0.
Rotary Coding Switch S5
The Extended protocol (traverse distance 629.146 meters) is set on the interface module using
rotary switch S5. The WCS read heads are addressed via a modified prompt bit. A total of one
byte more is transferred in the response telegram of the WCS Extended protocol. For more
information on the data format, refer to the WCS electrical manual (DOCT-5959).
Rotary switch S5 = switch position 0 for WCS standard (read head WCSxB-LS221*)
Rotary switch S5 = switch position 1 for WCS Extended 629.146 meters (read head WCS3B-
LS221E*)
Other states/switch positions are not permitted.
Up to four RS-485 (Extended) read heads can still be connected to an interface module.