2
0
2
0
-0
3
26
Communication with WCS Read Heads
5.2
Option-E
—
Extended, Type WCS3B-LS2*E*, RS-485
The read head
WCS3-Extended: WCS3B-LS*E*
with RS-485 interface is used for routes of
more than 314.573 m. In this case, the additional "E" in the type code identifies the extended
version for the extending code rail. Two standard code rail segments with a length of
0 ... 314.573 m are connected to each other with the WCS3-CS70-E code rail extender to
achieve a maximum code rail length of up to 629.146 m. The first code rail segment must
always be complete, or end with the position at 314.573 m. The second code rail segment can
have a shorter length of 314.573 m to X m, but must be used in descending position, starting at
314.573 m.
Extended data protocol with position output
Data protocol with position and velocity output
Request byte for read head
Byte
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
0
1
1
0
0
1
A1
A0
Response telegram from the read head
Byte
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 1 0
A1
A0
OVL
/VAL
DB
OUT ALL
OUT
ERR
Byte 2 0
0
0
0
0
XP19
XP18
XP17
XP16
Byte 3 0
XP15
XP14
XP13
XP12
XP11
XP10
XP09
XP08
Byte 4 0
XP07
XP06
XP05
XP04
XP03
XP02
XP01
XP00
Byte 5 0
xor
B1.7..B4.
7
xor
B1.6..B4.
6
xor
B1.5..B4.
5
xor
B1.4..B4.
4
xor
B1.3..B4.
3
xor
B1.2..B4.
2
xor
B1.1..B4.
1
xor
B1.0..B4.
0
Request byte for read head
Byte
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
1
1
1
0
0
1
A1
A0
Response telegram from the read head
Byte
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 1 0
A1
A0
OVL
/VAL
DB
OUT ALL
OUT
ERR
Byte 2 0
0
0
0
0
XP19
XP18
XP17
XP16
Byte 3 0
XP15
XP14
XP13
XP12
XP11
XP10
XP09
XP08
Byte 4 0
XP07
XP06
XP05
XP04
XP03
XP02
XP01
XP00
Byte 5 0
SST
SP6
SP5
SP4
SP3
SP2
SP1
SP0
Byte 6 0
B1.7..B5.
7
B1.6..B5.
6
1.5..B5.5 B1.4..B5.
4
B1.3..B5.
3
B1.2..B5.
2
B1.1..B5.
1
B1.0..B5.
0