Installation
Connecting the Power Supply
Connect the operating voltage (10 VDC...30 VDC) to terminals 1 and 2 of the 4-pin plug X2 on
the interface module. In addition, note the label on the module.
The "Power" LED lights up green.
Terminal X2
Equipotential Bonding Connection
The connection to equipotential bonding occurs automatically when attaching to the DIN
mounting rail.
PROFINET IO Communication Interface
This interface can be found on the module in the form of two 8-pin RJ45 sockets on the bottom
of the housing.
Insert the PROFINET connector into the RJ45 socket(s) labeled "RJ45 PROFINET IO."
Terminal
Description
1
UB+ (Pwr)
Operating voltage for interface module/
operating voltage for WCS read head
2
0 V (Pwr)
Ground for interface module/ground for WCS read head
3
not used
is not used
4
not used
is not used
Note
Ensure that the cable length to the neighboring Ethernet devices is at least
0.6 m.