VisuNet IXD
Mechanical Installation
Installation Steps
1.
Guide the IXD into the AG1 housing.
2.
While holding the IXD in the housing, install a few washers and socket head screws by hand to
keep the IXD in place.
3.
Insert a total of 14 x washers and 14 x screws in a uniform criss-cross pattern.
4.
Tighten the 14 x screws to 6 Nm. Apply a small amount of Loctite 243 to each screw prior to
installation.
3.8.5
Opening the AG1 Housing
The AG1 housing is hinged and opens to the left.
Opening the Housing
1.
Loosen the 4 screws on the back of the housing.
2.
Gently pull the front side of the housing toward you.
Warning!
Risk of Damage and Injury
Opening the AG1 housing before the pedestal is mounted onto the floor may
cause the housing and pedestal to tip over.
Mount the pedestal to the floor before opening the AG1 housing.