background image

VisuNet IXD

Mechanical Installation

 2

0

2

0

-0

4

39

3.8.4

AG1 Housing Assembly

Required Components

IXD prepared for AG1 installation with panel mount or AG1 adapter and gaskets

Loose screws and washers

Required Installation Tools

5 mm hex key for attaching screws from AG1 housing into IXD

Loctite 243

Figure 3.7

IXD assembly into AG1 housing configuration

Warning!

Risk of personal injury and equipment damage

Lifting the IXD housing on your own may cause injury or damage the device.

Installing the IXD into the AG1 Housing

Содержание VisuNet IXD PC-IXD2100-19U

Страница 1: ...VisuNet IXD RM IXD2100 19U PC IXD2100 19U Manual...

Страница 2: ...ion as well as the supplementary clause Expanded reservation of proprietor ship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs c...

Страница 3: ...lation with Pedestal 15 3 5 1 Preparation for Floor Mounting 15 3 5 2 Preparing the Pedestal 16 3 5 3 Attaching the IXD to the Yoke and Pedestal 17 3 5 4 Installing the Keyboard Tray Kit 24 3 5 5 Inst...

Страница 4: ...ontrol drawings Additional documents 1 2 Target Group Personnel Responsibility for planning assembly commissioning operation maintenance and dismount ing lies with the plant operator Only appropriatel...

Страница 5: ...This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbol indicates an imminent danger Non observance will result in person...

Страница 6: ...s a display panel with optional 10 finger multi touch sensors The display and touch sensors are optically bonded with the hardened front glass The thin client unit TCU1100 is a computing unit that run...

Страница 7: ...ata RM IXD Technical Data PC IXD Technical Data RM IXD and PC IXD Note For a description of the product model nomenclature view the VisuNet IXD PC or RM product datasheet on www pepperl fuchs com Hard...

Страница 8: ...neous devices and peripherals Ex i 1 x RS 232 Ex e 1 x RS 485 Ex e 1 x Ethernet 100 1000Base TX Ex e Electromagnetic compatibility Directive 2014 30 EU EN 61326 1 2013 industrial locations EN 61000 6...

Страница 9: ...l information such as electrical data and connection details refer to the manuals and instruction manuals of the individual components Display Unit DPU2100 J1 AC Power Supply Unit PSU1100 J1 AC N0 DC...

Страница 10: ...VisuNet IXD Product Description 2 3 Dimensions Panel Dimensions with Bezel Figure 2 1 Panel cut out dimensinons with bezel Label for DC Version in AG1 Housing Label for AC Version in AG1 Housing 542...

Страница 11: ...04 11 Yoke Mount Dimensions Figure 2 2 Yoke mount dimensions with optional sunshield and keyboard tray Dimensions with AG1 Housing and Pedestal Figure 2 3 Dimensions with AG1 housing and pedestal 663...

Страница 12: ...the mechanical installation chapters in this manual as well as the IXD and component datasheets on www pep perl fuchs com for information about available options 2 5 Disposal Follow all local and any...

Страница 13: ...n accordance with the instruc tions National laws and regulations must be observed The building installation must provide a 20 A overcurrent protection The installer must make a readily accessible dis...

Страница 14: ...sure to saltwater or associated vapor and mist To maintain the specified operating temperature install the device in a shaded environ ment Avoid direct sunlight on the IXD display components and housi...

Страница 15: ...er resulting from scratched display unit screen Scratches on a display unit front screen weaken the glass structure and may result in broken glass Explosion protection is no longer ensured if a displa...

Страница 16: ...set screws out of the pedestal in case of IXD hex wrench size 3 mm Preparing the Pedestal for Connection 1 Bend the grounding cable and place it within the pedestal tube 2 Remove the cable glands at...

Страница 17: ...y for connection 3 5 3 Attaching the IXD to the Yoke and Pedestal Warning Pinched cables Ensure that cables do not get pinched or damaged during installation Warning Risk of personal injury and equipm...

Страница 18: ...luding 2 x button head locking screws and 1 x spring plunger Preassembled gland plate with loose O ring Required Installation Tools 5 mm hex key for attaching screws to coupling and gland plate 4 mm h...

Страница 19: ...lled in the correct orientation the large treaded hole on the top portion of the yoke bracket 2 must be on the right side 3 Insert 2 x additional socket head screws 3 to secure the yoke frame to the p...

Страница 20: ...lift the IXD on each side and slide the inner washer into the yoke frame using a flat head screwdriver or similar 5 Tighten the knobs on each side while keeping the IXD positioned vertically 6 Insert...

Страница 21: ...on Installation Steps 1 Orient the gland plate assembly to match the guide pin 1 with the corresponding hole in the yoke frame 2 Guide the cables that have been routed through the pedestal up through...

Страница 22: ...ert 4 x socket head screws and 4 x flat washers 3 Tighten the screws in a diagonal pattern to 6 Nm Apply a small amount of Loctite 243 to the screws prior to installation 5 Adjust the length of the ca...

Страница 23: ...e ground hardware to 4 Nm Figure 3 4 Factory assembled ground connection from PSU to DPU Warning Connection to the ground bolts Connection to the ground bolts is mandatory Warning Customer responsibil...

Страница 24: ...board tray kit with loose hardware to be assembled to the yoke frame by the customer Required Installation Tools 3 mm hex key for attaching screws to the yoke bracket Flat head screwdriver Loctite 243...

Страница 25: ...for the shoulder screws 2 between the keyboard tray and the yoke Start to thread the shoulder screws on each side 4 Apply a small amount of Loctite 243 to the shoulder screws prior to installation Ti...

Страница 26: ...ponents Sunshield kit with loose hardware to be assembled to the yoke frame by the customer Required Installation Tools 4 mm hex key for attaching screws to the yoke frame Flat head screwdriver Attach...

Страница 27: ...ws 2 between the sunshield and the yoke frame Start to thread the shoulder screws on each side 4 The screws are threaded into locking nuts Tighten the screws until a slight amount of friction is evide...

Страница 28: ...with loose hardware to be assembled to the IXD by the customer Required Installation Tools 4 mm hex key for clamping screws 5 mm hex key for attaching panel mount brackets to the IXD Loctite 243 Panel...

Страница 29: ...ighten the screws to 6 Nm 6 Tighten the clamping screws in a uniform criss cross pattern until the gasket is fully compressed Torque will vary 7 If the panel is made out of thin or soft material use t...

Страница 30: ...upward 5 Attach 4 x flat head socket screws and tighten the screws to 4 5 Nm Apply a small amount of Loctite 243 to each screw prior to installation 6 Mount the two piece assembly to the wall with 4...

Страница 31: ...location with sufficient strength to hold the equipment It is the installer s responsibility to select the proper screws based on the installa tion conditions Warning Distance between housing and wal...

Страница 32: ...rdLine Pedestal Pedestals are shipped with an attached ground wire and screws for mounting the IXD housing to the pedestal 6 x M8 countersunk screws and 2 x M6 countersunk screws StandardLine Pedestal...

Страница 33: ...VisuNet IXD Mechanical Installation 2020 04 33 StandardLine Pedestal 1 Pre installed ground wire 2 Top cable opening 3 Cable glands 1 2 3...

Страница 34: ...gland nut and ferrule of the cable gland on the cable and slide them down the cable away from the pedestal Keep the nut and ferrule on the cable to tighten them in a later installation step 4 Attach t...

Страница 35: ...the cable through the cable entry and out the top of the pedestal 6 Pull the cable through the pedestal so that 50 cm of cable is hanging out of the top of the pedestal 7 Repeat the preceding steps fo...

Страница 36: ...from the top of the pedestal through the openings in the bottom of the housing 3 Align the mounting holes on the top of the pedestal with the mounting holes on the back of the housing Warning Risk of...

Страница 37: ...VisuNet IXD Mechanical Installation 2020 04 37 4 Tighten the 6 x M8 screws in a criss cross pattern to 20 Nm 5 Tighten the 2 x M6 screws to 12 Nm...

Страница 38: ...with a crane or the help of another person 2 Mount the pedestal onto the floor using suitable screws 3 Remove the protective foam blocks Warning Proper floor mounting It is the installer s responsibil...

Страница 39: ...and gaskets Loose screws and washers Required Installation Tools 5 mm hex key for attaching screws from AG1 housing into IXD Loctite 243 Figure 3 7 IXD assembly into AG1 housing configuration Warning...

Страница 40: ...the 14 x screws to 6 Nm Apply a small amount of Loctite 243 to each screw prior to installation 3 8 5 Opening the AG1 Housing The AG1 housing is hinged and opens to the left Opening the Housing 1 Loos...

Страница 41: ...alled ground wire that is connected from the inside top of the housing to the inside back of the housing The pedestal comes with a pre installed ground wire that you must route from the pedestal into...

Страница 42: ...Wires 1 Remove the nuts and washers from the PE stud on the inside back of the AG1 housing 2 Connect the pre installed ground wires from the the housing and pedestal to the ground bolt 3 Replace the...

Страница 43: ...VisuNet IXD Mechanical Installation 2020 04 43 Figure 3 8 Grounding Concept 1 Housing 2 Ground bolt hexagon socket 3 Contact washer 4 Nut 5 Cable lug 6 Flat washer 7 Spring washer 8 Nut...

Страница 44: ...nfiguration Tighten the ground hardware to 4 Nm Figure 3 9 Factory assembled ground connection from PSU to DPU Ground Connection between IXD System and AG1 Housing The ground connection between the IX...

Страница 45: ...04 45 3 8 7 Mounting the Keyboard 1 Remove the plug and screws from the bottom of the housing 2 To remove the plug open the housing see chapter 3 8 5 Hold the inside nut while removing the plug from...

Страница 46: ...re through the plug and tighten the screws to 4 5 Nm Note The keyboard is an intrinsically safe device Refer to the control drawings and relevant installation requirements For proper electrical termin...

Страница 47: ...T IXD WALLMOUNT 19U Wall mount kit 548327 KIT IXD PM 19U Panel mount kit 548266 AG1 19S 304A NN NN N0 AG1 housing 548392 KIT IXD19 KBT1 Keyboard tray for yoke mount 548393 KIT IXD19 KBT2 Keyboard tray...

Страница 48: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 6258B...

Отзывы: