ULTRATEMP ETI™ Hybrid Heater Installation and User’s Guide

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

Codes and Standards

UltraTemp ETi heaters are listed by UL as complying with the latest edition 
of the “UL Standard for Safety for Heating and Cooling Equipment”, UL 
1995, CSA C22.2 No. 236 and ANSI Z21.56
Installation must be in accordance with all local codes and/or the latest 
edition  of  the  National  Fuel  Gas  Code, ANSI  Z223.1  and  the  latest 
edition of the National Electrical Code, NFPA 70 (US). 
Installation  in  Canada  must  be  in  accordance  with  the  latest  CAN/
CGA-B149.1 or .2 and CSA C22.1 Canadian Electric Code, part 1.
This heater, when installed, must be electrically grounded and bonded 
in accordance with local codes, or, in absence of local codes, with the 
National Electrical Code, ANSI/NFPA70 (US) or in Canada in accordance 
with the Canadian Electric Code, part 1 as applicable. 

Consumer Information and Safety

UltraTemp ETi heaters are designed and manufactured to provide safe 
and reliable service when installed, operated and maintained according 
to the information in this manual and the installation codes referred to 
in later sections. Throughout the manual, safety warnings and cautions 
are identified by the “      “ symbol. Be sure to read and comply with all of 
the warnings and cautions.

This guide provides installation and operation instructions for this hybrid 
heater. Consult Pentair with any questions regarding this equipment.

Attention Installer: 

This guide contains important information about the 

installation, operation and safe use of this product. This information should 
be given to the owner and/or operator of this equipment after installation 
or left on or near the heater. 

Attention User: 

This manual contains important information that will help 

you in operating and maintaining this heater. Please retain it for future 
reference.

Important Notice: 

Before  installing  this  product,  read  and  follow  all 
warning notices and instructions which are included. 

Failure  to  follow  safety  warnings  and  instructions  can  result  in  severe 
injury, death, or property damage.  Call (800) 831-7133 for additional free 
copies of these instructions.

The following “Safety Rules for Hot Tubs” 
recommended by the U.S. Consumer Product 

Safety Commission should be observed when using the spa:

1.

  Spa or hot tub water temperatures should never exceed 104° F. [40° 

C.].  A temperature of 100° F. [38° C.] is considered safe for a healthy 
adult.  Special caution is suggested for young children. Prolonged 
immersion in hot water can induce hyperthermia.

2.

  Drinking of alcoholic beverages before or during spa or hot tub 

use can cause drowsiness which could lead to unconsciousness 
and subsequently result in drowning.

3.

 

Pregnant  women  beware

!    Soaking  in  water  above  100°  F. 

[38° C.] can cause fetal damage during the first three months of 
pregnancy (which may result in the birth of a brain-damaged or 
deformed child).  Pregnant women should stick to the 100° F. [38° 
C.] maximum rule.

4.

  Before  entering  the  spa  or  hot  tub,  the  user  should  check  the 

water temperature with an accurate thermometer. Spa or hot tub 
thermostats may err in regulating water temperatures.

5.

  Persons  with  a  medical  history  of  heart  disease,  circulatory 

problems,  diabetes  or  blood  pressure  problems  should  obtain 
their physician’s advice before using spas or hot tubs.

6.

  Persons  taking  medication  which  induce  drowsiness,  such  as 

tranquilizers,  antihistamines  or  anticoagulants  should  not  use 
spas or hot tubs.

For units intended for use in other than single-family 
dwellings,  a  clearly  labeled  emergency  switch 

shall be provided as part of the installation. The switch shall be readily 
accessible to the occupants and shall be installed at least 5 feet [1.52 
m] away, adjacent to, and within sight of the unit.

Do not permit children to use this product.

RISK OF ELECTRICAL SHOCK OR 
ELECTROCUTION.

The  electrical  supply  to  this  product  must  be  installed  by  a  licensed, 
certified electrician or qualified personnel in accordance with the National 
Electrical Code and all applicable local codes and ordinances. Improper 
installation will create an electrical hazard which could result in death or 
serious injury to pool or spa users, installers, or others due to electrical 
shock, and may also cause damage to property. Read and follow the 
specific instructions inside this guide.

Should  overheating  occur  or  the  gas  supply  fail 
to  shut  off,  turn  off  the  manual  gas  control  valve 

to the heater. Do not use this heater if any part has been under water. 
Immediately call a qualified service technician to inspect the heater and 
to replace any part of control system and gas control which has been 
underwater.

Risk  of  fire,  carbon  monoxide  poisoning,  or 
asphyxiation  if  exhaust  venting  system  leaks.

 

Only qualified service technicians should attempt to service the heater, as 
leakage of exhaust products or flammable gas may result from incorrect 
servicing.

The U.S. Consumer Product Safety Commission warns 
that  elevated  water  temperature  can  be  hazardous. 

See below for water temperature guidelines before setting temperature. 

This is the safety alert symbol. When you see this 
symbol on your system or in this manual, look for 
one of the following signal words and be alert to 
the potential for personal injury.
Warns  about  hazards  that  can  cause  death, 
serious personal injury, or major property damage 
if ignored.
Warns  about  hazards  that  may  cause  death, 
serious personal injury, or major property damage 
if ignored.
Warns about hazards that may or can cause minor 
personal injury or property damage if ignored.

             NOTE

           Indicates special instructions not related to  

 

 

                hazards.

Carefully read and follow all safety instructions in this manual and on 
equipment. Keep safety labels in good condition; replace if missing or 
damaged.

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Improper installation, adjustment, alteration, service 
or  maintenance  can  cause  property  damage, 

personal injury or death. Installation and service must be performed 
by a qualified installer, service agency or the gas supplier.

ENGLISH

ii

Содержание ULTRATEMP ETi 220

Страница 1: ...ENGLISH INSTALLATION AND USER S GUIDE HYBRID HEATER IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ULTRATEMP ETi ESPA OL FRAN AIS ENGLISH...

Страница 2: ...to EasyTouch via Heater Spade Terminals Connecting to EasyTouch via RS 485 Connector Pin Configuration for Heater Control Board to EasyTouch Connecting EasyTouch to the Heater Operating the Heater Swi...

Страница 3: ...the 100 F 38 C maximum rule 4 Before entering the spa or hot tub the user should check the water temperature with an accurate thermometer Spa or hot tub thermostats may err in regulating water temper...

Страница 4: ...rbon monoxide detectors must be periodically inspected for proper operation so as to insure continued safety Broken or malfunctioning carbon monoxide detectors must be replaced immediately This heater...

Страница 5: ...ral purpose water heater 4 The heater should be located in an area where leakage of the heater or connections will not result in damage to the area adjacent to the heater or to the structure When such...

Страница 6: ...acket 4 Electric cutout switch that will interrupt all power to the unit This switch must be within line of sight of the heater Check local codes for requirements 5 Watertight conduit to run the elect...

Страница 7: ...oth the plumbing and control panel side of the heater This will provide necessary room for servicing 2 At least 12 inches 305 mm of clearance must be available on all the other sides of the heater to...

Страница 8: ...SIDE VIEW Building From building wall Exhaust Grill Vent 12 30 5cm Roof Overhang 4 1 2m 4 1 2m 12 30 5cm Must be at least 3 ft 0 9 m above any forced air inlet located within a 10 ft 3 5 m radius Vent...

Страница 9: ...r drains and or pipes particularly those that are metal Ensure that the drain drainpipe and anything that will come in contact with the condensate can withstand the acidity Damage caused by failure to...

Страница 10: ...location on the equipment pad 2 Place the clamps at the base of the heater in the eight 8 locations shown in Figure 5 Note Bolts and washers are not included with the heater The installer must provid...

Страница 11: ...Install a chemical resistant one way check valve between the heater and the chemical feeder to prevent back siphoning through the heater when the pump is off Note If the heater is plumbed in backward...

Страница 12: ...ressure Relief Valve Kit P N 475943 complying with the ANSI ASME Boiler and Pressure Vessel Code having a capacity equal to the Btu hr rating of the heater Note The relief pressure of the valve MUST N...

Страница 13: ...um 3 PVC Pipe 2 PVC Pipe Flow Meter To Pool 3 Ball Valve Bypass Check Valves are optional on heater inlets but will help for system balancing 36 914 mm 2 PVC Pipe 2 PVC Pipe 2 PVC Pipe 3 PVC Pipe 3 PV...

Страница 14: ...e plumbing system On some installations the piping from the heater to the pool is very short The back pressure could be too low to trigger the pressure switch If this happens install a directional fit...

Страница 15: ...ipe as this may cause damage to the gas valve which may result in heater failure The gas meter should be checked to make sure that it will supply enough gas to the heater and any other appliances that...

Страница 16: ...lve Risk of explosion if a unit burning propane gas is installed in a pit or other low spot Propane is heavier than air Do not install the heater using propane in pits or other locations where gas mig...

Страница 17: ...Remove the long side service panel of the heater cabinet There is no need to remove the star head screws 2 Remove the short side service panel to the heater electrical compartment 3 Remove the sheet m...

Страница 18: ...14 ULTRATEMP ETI Hybrid Heater Installation and User s Guide Wiring Diagram Input Side...

Страница 19: ...ULTRATEMP ETI Hybrid Heater Installation and User s Guide 15 Wiring Diagram Output Side P N 476088 B 4 10 18 ENGLISH...

Страница 20: ...s 1 Turn off the power to both the remote pool spa control system and the heater 2 Remove the side panel of the heater cabinet you do not need to remove the star head screw at the top left corner 3 Re...

Страница 21: ...Run a UL approved conductor cable from the heater to the Load Center 5 Route the cable up through the low voltage raceway located on the left of the Load Center to the Personality Board see image belo...

Страница 22: ...tem power before making any connections 2 Unlatch the EasyTouch load center front door spring latches and open the front door 3 Remove the cover panel screws securing the high voltage cover panel and...

Страница 23: ...ace the side panel 8 Restore power to the heater and the EasyTouch control system 9 Press the MENU SELECT button to scroll to the Remote Mode screen Toggle the selection by pressing one of the arrows...

Страница 24: ...he cost of operating your heater without sacrificing performance 1 The American Red Cross recommends a maximum water temperature of 83 86 F 28 3 30 C Use an accurate pool thermometer A difference of 3...

Страница 25: ...ore details and explanations regarding heater features and programming Pre Startup 1 This appliance does not have a pilot It is equipped with an ignition device which automatically lights the burner D...

Страница 26: ...bout 15 seconds the burner should fire When operating for the first time the burner may not fire on the first try because of air in the gas line If it does not fire at first push the ON OFF button wai...

Страница 27: ...e water pressure switch refer back to page 10 Water Pressure Switch Adjustment Turn the star wheel on the switch clockwise to raise setting heater below the pool level and counterclockwise to lower th...

Страница 28: ...loat Switch CFS The Float Switch CFS is a sensing application that shuts down the heater once the condensate level exceeds the permitted level in the condensate container Ignition Module Operation The...

Страница 29: ...an RS 485 connected IntelliFlo pump when the heater is attempting to heat to its set point Suction Temperature Screen Shows the suction line temperature of the refrigerant This screen only appears if...

Страница 30: ...T ___ Remote Mode Relay In Relay Remote Mode operation the heater is started and stopped by remote relays which are connected to the remote POOL COMMON and SPA quick connect terminals on the back of t...

Страница 31: ...h an RS 485 connected IntelliFlo or IntelliPro pump to ensure water is flowing through the heater when water heating is required Note This feature requires that an RS 485 communication cable be connec...

Страница 32: ...message for two 2 minutes FIVE ALARMS Indicates that five 5 faults have occurred in one 1 hour This fault will automatically reset in one 1 hour or can be manually reset by pressing the ON OFF button...

Страница 33: ...using the UP and DOWN arrows Defrost Screen Allows the user to Enable Disable Defrost feature Heat Pump Input Screen and Output Screen Diagnostic displays showing the status of the input sensors and...

Страница 34: ...e the heater compressor stops The heater evaporator fan will continue to run and will draw air over the evaporator fins for about 15 minutes If the refrigerant sensor detects a temperature above the d...

Страница 35: ...NTY CYCLES number of cycles over the lifespan of the unit Press the UP and DOWN arrows to scroll through the Timers and Counters The last screen provides an option to reset the Run Time Log Time and C...

Страница 36: ...of your pool water is available from your local pool supply store If pH becomes too high over alkaline it has these effects 1 Reduces the ability of chlorine to destroy bacteria and algae 2 Water beco...

Страница 37: ...e the heat pump is in operation The heater base is designed to allow the condensation to exit through the bottom drain port when the unit is running The condensation will increase as the outdoor air h...

Страница 38: ...to partially drain then reassemble 8 Use a blower connected to the outlet of the heater to remove all remaining water from the heater 9 Cover air inlet grate with a plastic bag to prevent bugs leaves...

Страница 39: ...80W Current Amp 80A 63RH 80W Capacity Btu h 50A 63RH 80W COP 50A 63RH 80W Power Input KW 50A 63RH 80W Current Amp 50A 63RH 80W Min Circuit Ampacity Amp 148 4 150 Electrical Supply Voltage Requirement...

Страница 40: ...s closely matched by the ambient and water flow conditions 0 1 2 3 4 5 6 7 8 9 10 11 12 0 10 20 30 40 50 60 70 80 90 100 110 120 Pressure Drop psi Water Flow gpm UltraTemp ETI Pressure Drop Curve Pres...

Страница 41: ...If shows open replace thermistor If good replace control board SUCTION TH SHORT Alarm Defrost refrigerant temperature sensor circuit is shorted Bad thermistor or bad control board Use the 10k ohm resi...

Страница 42: ...ed Call for professional servicing LOW REFRIG Alarm Refrigerant low pressure switch is open 1 Low refrigerant in system Call for professional servicing 2 Air and water temperatures too cold to operate...

Страница 43: ...nector pin 1 and ignition control module terminal F2 On call for heat if blower starts but shuts off within 30 seconds refer to Faulty Air Flow Switch or Switch Wiring troubleshooting below 6 Faulty a...

Страница 44: ...ore attempting to Troubleshoot Electrical Box 1 Heater condensate drain hose restriction Verify proper hose routing from heater base Ensure there are no loops kinks or elevated portions between hose e...

Страница 45: ...heater Unit ON and Set Temperature is above Actual but Unit is not heating No Alarms Heater is in the five minute safety delay and Compressor has not started Faulty Compressor Faulty Capacitor Compre...

Страница 46: ...ue Contact certified electrician BURNER TROUBLESHOOTING Loud high pitched whine Flame is too rich Verify pressure tap between gas valve and blower inlet See page 11 and verify that the gas regulator s...

Страница 47: ...ULTRATEMP ETI Hybrid Heater Installation and User s Guide 43 REPLACEMENT PARTS Heater Parts Breakdown REFRIGERATION OUTER SHELL p 44 GAS SYSTEM p 45 ELECTRICAL p 46 PLUMBING p 47 ENGLISH...

Страница 48: ...ck 9 475230Z Compressor Blanket 10 475948Z Titanium Heat Exchanger Tie Down Bracket 11 475949Z Titanium Heat Exchanger 12 473735Z Compressor ZP70 Item Part Description 13 473121 Drier Single Direction...

Страница 49: ...st Replacement Kit 25 475877 Exhaust Gasket Kit 2 Pieces 26 475989 Gas Engine Spark Electrodes 27 475898 Burner Assembly 28 462023 Flame Sensor Item Part Description 29 475897Z Heat Exchanger 100K BTU...

Страница 50: ...Wire Harness Heat Pump Inputs 35 475930Z Wire Harness Outputs 36 475926Z Wire Harness Spark Plugs 37 475931Z Wire Harness Gas Blower 38 473155 Transformer 39 475933Z Ignition Control Module Item Part...

Страница 51: ...75941 Switch Automatic Gas Shutoff 140 F 56 475955Z Switch High Limit 127 F 57 471566 Probe Thermistor Water Temperature 58 473381 Union PVC 2in 59 475953Z QRC Clip 60 98218900 Drain Plug 1 4 NPT Item...

Страница 52: ...essly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Po...

Отзывы: