K

e

y

Description

Size

Size

Size

Size

Size

Size

Size

Size

Size

No

500

600

715

850

1010

1200

1430

1670

1825

37

Inlet/Outlet Header, Machined

10364500

10364500

10364500

10364500

10364500

10364500

10364500

10364500

10364500

[S0094300 Glassed Cast Iron]

Inlet/Outlet Header, Machined

10364501

10364501

10364501

10364501

10364501

10364501

10364501

10364501

10364501

[S0064000 Bronze]

38

Flange, 2-1/2" NPT Machined

10391303

10391303

10391303

10391303

10391303

10391303

10391303

10391303

10391303

[S0063600 Cast Iron]

Flange, 2-1/2" NPT Machined

10391304

10391304

10391304

10391304

10391304

10391304

10391304

10391304

10391304

[S0064400 Bronze]

39

Tee, Machined Flange

20130002

20130002

20130002

20130002

20130002

20130002

20130002

20130002

20130002

[Glassed Cast Iron]

Tee, Machined Flange [Bronze]

20150303

20150303

20150303

20150303

20150303

20150303

20150303

20150303

20150303

40

Baffle, Water Inlet

10338300

10338300

10338300

10338300

10338300

10338300

10338300

10338300

10338300

41

Barrier, Water

20230101

20230101

20230101

20230101

20230101

20230101

20230101

20230101

20230101

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

42

Flange Gasket

S0063700

S0063700

S0063700

S0063700

S0063700

S0063700

S0063700

S0063700

S0063700

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

43

Header Gasket w/Barrier

S0095100

S0095100

S0095100

S0095100

S0095100

S0095100

S0095100

S0095100

S0095100

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

44

Well, Immersion

E2074000

E2074000

E2074000

E2074000

E2074000

E2074000

E2074000

E2074000

E274000

45

Well, High Limit

E0025900

E0025900

E0025900

E0025900

E0025900

E0025900

E0025900

E0025900

E0025900

46

Valve, Pressure Relief

A0063300

A0063300

A0063300

A0063600

A0063600

A0063600

A0063600

A0063600

A0063600

3/4 NPT 75 PSI

47

Temperature Gauge

A2089500

A2089500

A2089500

A2089500

A2089500

A2089500

A2089500

A2089500

A2089500

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

48

Flow Switch {Indoor}

E0013100

E0013100

E0013100

E0013100

E0013100

E0013100

E0013100

E0013100

E0013100

Flow Switch {Outdoor}

E0013000

E0013000

E0013000

E0013000

E0013000

E0013000

E0013000

E0013000

E0013000

49

Pump, Motor, Impeller

A2001800

A2001800

A2001800

A2001800

A2001800

A2001800

A2001800

A2001800

A2001900

50

Pump Adapter {Glassed Cast Iron}

10364200

10364200

10364200

10364200

10364200

10364200

10364200

10364200

10364200

Pump Adapter {Cast Bronze}

10364201

10364201

10364201

10364201

10364201

10364201

10364201

10364201

10364201

51

Pump Housing {Glassed Cast Iron}

10261501

10261501

10261501

10261501

10261501

10261501

10261501

10261501

10261501

Pump Housing {Bronze}

10483301

10483301

10483301

10483301

10483301

10483301

10483301

10483301

10483301

52

Baffle, Diffuser

10338400

10338400

10338400

10338400

10338400

10338400

10338400

10338400

10338400

53

Pump Housing Gasket

S0024600

S0024600

S0024600

S0024600

S0024600

S0024600

S0024600

S0024600

S0024600

54

Pump Motor Gasket,

A0021400

A0021400

A0021400

A0021400

A0021400

A0021400

A0021400

A0021400

A0021400

NOTE: Numbers in (

) represent quantity required for each size. Quantity is one otherwise.

Содержание MegaTherm MT 1010

Страница 1: ...nance Improper installation and or operation could create carbon monoxide gas in flue gases which could cause serious injury property damage or death Improper installation and or operation will void t...

Страница 2: ...s 9 2 7 Boiler By Pass Piping 9 2 8 Temperature Sensor Placement and Installation 10 2 9 Automatic Chlorinators 10 SECTION 3 Operation 3 1 Controls General 11 3 2 Initial Start Up 11 3 3 Safety Shutof...

Страница 3: ...he procedures MODEL MT POOL REVISION P PUMP U S Q PUMP CAN HEAT EXCHANGER C GLASS LINED COPPER N GLASS LINES CU NI K BRONZE COPPER S BRONZE CU NI VERSION 1 8 TUBE B 10 TUBE I INDOOR E OUTDOOR FUEL N N...

Страница 4: ...ide sufficient air supply for proper combustion and ventilation of the surrounding area as outlined in the latest edition of ANSI standard Z223 1 and any local codes that may be applicable Inadequate...

Страница 5: ...al used to maintain clearances and prevent physical damage and separation of joints Avoid terminating boiler vents near air conditioning or air supply fans The fans can pick up exhausted flue products...

Страница 6: ...a summer exhaust fan Close all fireplace dampers 4 Place in operation the appliance being inspected Follow the lighting instructions for the unit Adjust the thermostat so the appliance will operate c...

Страница 7: ...n Outdoor installations are not recommended in areas where the danger of snow blockage exists WARNING Liquefied petroleum gas is heavier than air Therefore the pool heating boiler should not be instal...

Страница 8: ...rwise 2 The 1825 models are supplied with 3 4 HP pump motors All other models are supplied with 1 2 HP pump motors Consult the National Electrical Code or the Canadian Electrical Code regarding branch...

Страница 9: ...ed by the momentary back siphoning of hot water from the heater when the filter pump stops running The pressure relief valve installed in the tapped opening provided in the outlet header see Figure 9...

Страница 10: ...ic Chlorinators A concentration of chlorine in the heater can be very destructive therefore the following rules about the installation and operation of such devices must be followed 1 The chlorinator...

Страница 11: ...he temperature sensor thermistor is located in the filter circulation piping see Section 2 8 3 Boiler Power On Off Auto Switch This provides for constant or automatic pump operation 4 High Limit Contr...

Страница 12: ...cally lit when the operating controls call for heat If the pilot flame fails for any reason the main valve is shut off within one second and the pilot spark ignition is initiated until the pilot flame...

Страница 13: ...etailed above should be less than 142 F The normal range will be 10 to 37 F higher than the inlet temperature If it exceeds 142 F please contact the Service Department at 800 900 9276 extension 5406 f...

Страница 14: ...ic pools or spa pools are usually piped and controlled so that very warm or hot water often with air injection is forced at high velocity into a confined area of a swimming pool or into a small separa...

Страница 15: ...m are unobstructed 6 Check for fouling on the external surfaces of the heat exchanger every six months NOTE after installation and first start up check the heat exchanger for fouling after the followi...

Страница 16: ...itizing chemicals also adds greatly to the mineral content of the pool If the concentration of minerals in the pool is permitted to become too high the minerals will precipitate out of the water and d...

Страница 17: ...at gas valve terminals Check continuity of actuator burned out or shorted coil If open circuit or short is indicated replace coil or operator G Pump does not run G Operate in manual Check power to pum...

Страница 18: ...Rear 10548401 10548402 10548403 10548404 15 Saddle Assembly End Tile 10533600 10533600 10533600 10533600 10533600 10533600 10533600 10533600 10533600 2 2 2 2 2 2 2 2 2 16 Lower End Panel 10540701 1054...

Страница 19: ...MegaTherm Commercial Pool Heating Boiler Page 19 Figure 17 Parts Identification...

Страница 20: ...Assembly Copper Tubes 10534701 10534702 10534703 10534704 10534705 10534706 10534707 Cast Iron Tubs Indoor 8 Tube Assembly Copper Tubes 10542901 10542902 10542903 10542904 10542905 10542906 10542907 B...

Страница 21: ...ll Immersion E2074000 E2074000 E2074000 E2074000 E2074000 E2074000 E2074000 E2074000 E274000 45 Well High Limit E0025900 E0025900 E0025900 E0025900 E0025900 E0025900 E0025900 E0025900 E0025900 46 Valv...

Страница 22: ...W0034400 W0034400 W0034400 W0034400 Standing Pilot LP Pilot Burner Honeywell W0034300 W0034300 W0034300 W0034300 W0034300 W0034300 W0034300 W0034300 W0034300 IID Pilot Nat Pilot Burner Honeywell W2001...

Страница 23: ...0 E2103900 E2103900 E2103900 E2103900 E2103900 E2103900 E2103900 74 Controller Water Temp E2103800 E2103800 E2103800 E2103800 E2103800 E2103800 E2103800 E2103800 E2103800 75 Sensor Water Temp E2103600...

Страница 24: ...d Spa Page 24 Figure 18 Tile Assemblies When ordering tiles Assembly number is for all tiles Part numbers shown for the front of unit are the same for the rear tiles Check dimensions of old tile as sh...

Страница 25: ...MegaTherm Commercial Pool Heating Boiler Page 25 Figure 19 Outdoor Parts 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 13 20...

Страница 26: ...03 10658104 10658105 10658106 10658107 10658108 10658109 3 Upper Rear Louver shield 10657101 10657102 10657103 10657104 10657105 10657106 10657107 10657108 10657109 4 Upper Rear Panel 10658701 1065870...

Страница 27: ...1 10659302 10659303 10659304 10659305 10659306 10659307 10659308 10659309 20 Pump Cover Assembly 20050100 20050100 20050100 20050100 20050100 20050100 20050100 20050100 20050100 Pump Parts Pump Couple...

Страница 28: ...Pentair Water Commercial Pool and Spa Page 28...

Страница 29: ...MegaTherm Commercial Pool Heating Boiler Page 29...

Страница 30: ...Pentair Water Commercial Pool and Spa Page 30...

Страница 31: ...MegaTherm Commercial Pool Heating Boiler Page 31...

Страница 32: ...000 Trademarks and disclaimers MegaTherm and the Pentair Commercial Pool and Spa logo are trademarks of Pentair Water Pool and Spa Inc Other trade marks and trade names may be used in this document to...

Отзывы: