MASTER SETTINGS PROGRAMMING CONTINUED
Regeneration Screen
From the main Master Settings screen press the
regen
button to display the Regeneration screen.
CAUTION
Adjusting Regeneration settings will turn any set relays off. Any required relays will need to be reprogrammed in
the
Relay
Output
screen.
•
regen flow
: Contains settings for the type of regenerant flow to be used in the valve. Changes to this setting affects
the cycle steps displayed in the Regeneration Cycle Wheel on the Home screen. Regenerant flow cycle steps are
described below.
•
downflow
: Cycle steps are as follows: Backwash, Draw, Rapid Rinse, Tank Refill.
•
upflow
: Cycle steps are as follows: Draw, Backwash, Rapid Rinse, Tank Refill.
•
downflow 2X backwash
: Cycle steps are as follows: Backwash, Draw, Backwash, Rapid Rinse, Tank Refill.
•
custom upflow / downflow / filter: Allows for up to 20 programmable cycle steps.
•
variable refill
: (softener delayed only) Cycle steps are as follows: Refill, Pause, Draw, Backwash, Rinse. Variable refill
calculates refill time based on salt dosage, media volume, and BLFC size.
Relay Output Screen
From the main Master Settings screen press the
relay
button to display the Relay Outputs screen.
PENTAIR INTELLIWATER CONNECTED WATER SOFTENER