27
INTELLIFLO
®
VS+SVRS and INTELLIPRO
®
VS+SVRS Variable Speed Pump Installation and User’s Guide
26
INTELLIFLO
®
VS+SVRS and INTELLIPRO
®
VS+SVRS Variable Speed Pump Installation and User’s Guide
5. Lower down the hinged control panel to access the EasyTouch
®
Control System motherboard.
6. Route the communication cable into the lower plastic grommet, up through the low voltage
raceway to the EasyTouch system load center motherboard.
7. Strip back the cable conductors ¼ inch. Insert the two wires into the screw terminals on the
board. Secure the wires with the screws.
8.
EasyTouch control system to pump pin configuration:
• Pump: Connect pin 6 (green) to EasyTouch screw terminal pin 2 (green)
• Pump: Connect pin 7 (yellow) to EasyTouch screw terminal pin 3 (yellow)
9. Insert the screw terminal onto the EasyTouch
COMPORT (J20)
board connector.
Note:
Multiple wires may be inserted into a single screw terminal.
Pin configuration
EasyTouch (J20)
screw terminal
EasyTouch
screw terminal
connector
IntelliFlo
(2-wire cable)
2 (GRN)
GREEN (Pin 6)
3 (YEL)
YELLOW (Pin 7)
Pin 6
(Green)
Pin 7 (Yellow)
Pump connector pin configuration
EasyTouch
COMPORT
(J20)
Indoor Control Panel
IntelliChlor
IntelliPro
RF Transceiver
Low voltage
Raceway
Control panel