Section 3
Operating the Pump
This section describes how to operate the IntelliFlo
®
VS+SVRS Pump using the control panel buttons and
menu features.
Note: Speed 1 is the default filtration speed. When setting-up the pump, the user must set the
pump’s internal clock and establish an operation schedule by following the steps in this manual.
Please refer to user’s guide sections: ‘Set Time’ (page 10) and ‘Speed 1-8 (Schedule a Time to Run
the Pump)’ (page 16).
Starting the pump
To start the pump
1. Be sure the pump is powered on and the green power LED is on.
2. Select one of the speed buttons, then press the
Start
button (LED on) to start the pump.
Stopping the pump
To stop the pump
• Press the
Stop
button to stop the pump.
Note:
The pump can automatically restart if the communication cable is connected.
Servicing Equipment (Disconnect Power to Pump)
• When servicing equipment (filters, heaters, chlorinators etc.), disconnect the communication
cable, and switch OFF circuit breaker to remove power from the pump.
Operating the pump at preset speeds
The pump is programmed with four default speeds of
1100
,
1500,
2350
and
3110
RPM. A
Speed
button is assigned to each of the preset speeds as shown.
To operate the pump at one of the four preset speeds
1. Be sure the pump is powered on and the green power LED is on.
2. Press the
Speed
button (
1
-
4
) corresponding to the desired preset speed, and release quickly.
The LED above the
Speed
button will come on as shown.
3. Press the
Start
button. The pump will ramp to the selected preset speed.
Adjusting the pump speed
1.
While the pump is running, press the
Up Arrow
to increase speed setting.
2.
Press the
Down Arrow
to decrease speed Setting.
3.
Press and hold down a
Speed Button
for three (3) seconds to save speed to the button or
press the
Enter
button to save the speed.
Speed
1
Speed
2
Speed
3
Speed
4
LED lit