Installer manual Fleck 5800 XTR - Programming
82 / 126
Ref. MKT-IM-006 / E - 12.11.2019
6.3.10
Water Saver Regen screen
From the secondary master settings screen press the
water saver regen.
button to display the
water saver regen. screen.
Water Saver Regen
water saver
regen.
off
water saver regen.
: Set to off. When activated, the backwash duration is reduced by 50% and the
fat rinse duration is reduced by 66%, classic regeneration happening still at the programmed
regeneration frequency (1-25 regenerations).
Press
to save and to return to the master settings screen or press
to return to the master
settings screen without saving.
6.3.11
Remote Regeneration screen
From the secondary master settings screen press the
remote regen
button to display the remote
regeneration screen.
Remote Regeneration
remote signal
duration
off
remote signal duration
: Contains settings for triggering a regeneration via a remote input. Set a
timing in seconds for contact closure in order to trigger the regeneration.
Connect a remote switch (such as a differential pressure switch) to the remote start input
terminals on the back of the XTR controller board. See Electrical connections [
Page 45]. When
the remote switch remains closed for the number of seconds specified in the remote regeneration
screen, a regeneration will be triggered regardless of volume, capacity, or time remaining until
the next scheduled regeneration.
Press
to save and to return to the master settings screen or press
to return to the master
settings screen without saving.