Installer manual Fleck 5800 XTR - Troubleshooting
Ref. MKT-IM-006 / E - 12.11.2019
111 / 126
Problem
Cause
Solution
Loss of water pressure.
Scaling/Fouling of inlet pipe.
Clean or replace pipeline.
Pretreat to prevent.
Fouled resin.
Clean the resin. Pretreat to
prevent.
Improper backwash.
Too many resin fines and/or
sediment. Call dealer, reset
backwash flow rate, and/or adjust
time.
Excessive water in brine
tank and/or salty water to
service.
Plugged Drain Line.
Check flow to drain. Clean flow
control.
Dirty or damaged brine valve.
Clean or replace brine valve.
Plugged injector.
Clean injector and replace screen.
Low inlet pressure.
Increase pressure to allow
injector to perform properly (1.4
bar minimum).
Controller not cycling.
Replace controller.
Softener fails to use salt.
Plugged/restricted drain line.
Clean drain line and/or flow
control.
Injector is plugged.
Clean or replace injector and
screen.
No water in brine tank.
Check for restriction in BLFC.
Ensure safety float is not stuck.
Water pressure is too low.
Line pressure must be at least
1.4 bar.
Brine line injects air during brine
draw.
Check brine line for air leaks.
Internal valve leak.
Call dealer. Check piston, seals
and spacers for scratches and
dents.
Valve cycles continuously. Faulty controller.
Replace controller.
Wrong programming.
Check programming.
Continuous flow to drain.
Foreign material in control valve.
Call dealer. Clean valve, rebuild
unit.
Internal control valve leakage.
Valve jammed in regeneration
position.
Motor stopped or jammed during
regeneration.
Replace motor.
Содержание Fleck 5800 XTR
Страница 1: ...FLECK 5800 XTR INSTALLER MANUAL WATER PURIFICATION...
Страница 17: ...Installer manual Fleck 5800 XTR Description Ref MKT IM 006 E 12 11 2019 17 126 3 3 Outline drawing...
Страница 103: ...Installer manual Fleck 5800 XTR Maintenance Ref MKT IM 006 E 12 11 2019 103 126...
Страница 126: ...www pentairaquaeurope com...