Installer manual Fleck 5800 XTR - Programming
Ref. MKT-IM-006 / E - 12.11.2019
81 / 126
Info
Not available with the timeclock regeneration type.
Meter
meter type
generic
emerg.
regen
off
na
0.75 turbine
meter type
: Contains settings for the type of meter installed with the system. The standard setting
are:
• 0.75" Turbine for 5800;
• 1.25" Turbine for 5810 and 5812.
generic
: If meter type is set to generic, permit to set up the number of pulses per litre.
continuous flow detect
: When active, triggers an alarm when continuous flow of 0.5 gpm or 1 Lpm
is detected by the flow meter over a 8 hours period.
Press
to save and to return to the master settings screen or press
to return to the master
settings screen without saving.
6.3.9
Settings review
From the master settings screen press the
settings review
button to display the settings review
screen, which display a read-only summary of all programmed settings in the controller.
Format
language
units
hardness units
mg/L
metric
english
Use the navigation arrows at the top of the screen to scroll through the parameters currently set
in the controller. The settings review screens are formatted similarly to the corresponding screen
where each parameter was set.
Press
to return to master settings.