![Pentair Biffi ICON 2000 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/pentair/biffi-icon-2000/biffi-icon-2000_instructions-and-operating-manual_1524512070.webp)
2
Biffi
ICON 2000 / ICON 2000 AD
Addendum C to InstruCtIon And operAtIng mAnuAl
IECEx INE XX�ZZZZ
IECEx reference certificate (CoC)
XX ATEX ZZZZ
ATEX reference certificate
0080
Notified body for ATEX quality assurance (INERIS)
II
Group II (surface industries)
2
Category 2 apparatus
G
Explosive atmospheres caused by gas, mists or vapors
D
Explosive atmospheres caused by gas dusts
IP66/68
Degree of protection
Hazardous zone
Zone
Categories according to 94/9/eC directive
Gas, mist or vapors
0
1G
Gas, mists or vapors
1
2G or 1G
Gas, mists or vapors
2
3G or 2G or 1G
Dust
20
1D
Dust
21
2D or 1D
Dust
22
3D or 2D or 1D
3� APPlICAblE DIRECTIVES,
GENERAl STANDARDS AND
NORMS
equipMenT prOTeCTiOn leVel (epl) en 60079-14
explosive atmosphere
Zone
epl
Gas
0
Ga
Gas
1
Ga or Gb
Gas
2
Ga or Gb or Gc
Dust
20
Da
Dust
21
Da or Db
Dust
22
Da or Db or Dc
2006/42/EC
Machinery Directive
2004/108/EC
EMC Directive
2006/95/EC
low Voltage Directive
94/9/EC
ATEX Directive
EN ISO 12100-1
Safety of machinery -
basic concepts, general
principles for design�
Part 1-basic terminology,
methodology
EN ISO 12100-2
Safety of machinery -
basic concepts, general
principles for design�
Part 2-Technical principles
and specification
EN 60079-0: 2009
IEC 60079-0: 2011
EN 60079-1: 2007
IEC 60079-1: 2007
EN 60079-7: 2007
IEC 60079-7: 2006
EN 60079-11: 2012 IEC 60079-11: 2011
EN 60079-31: 2009 IEC 60079-31: 2008
EN 13463-1: 2009
EN 13463-5: 2003
4� TERMS AND CONDITIONS
biffi Italia guarantees each single product to
be free from defects and to conform to current
goods specifications� Except when differently
specified, the warranty period in one year from
the date of installation by the first user, or
eighteen months from the date of shipment to
the first user, whichever occurs first�
5� MANufACTuRER’S
lIAbIlITy
biffi Italia declines all liability in the event of:
- use of product in contravention of local safety
at work legislation�
- Incorrect installation, disregard or incorrect
application of the instructions provided on
the product nameplate and in VCIOM-01232
main Instruction and Operating Manual and
relevant Addendum C�
- Modification of the product without biffi’s
authorisation�
- Work done on the product by unqualified or
unsuitable personnel�
No warranty is given for products which
have been subject to improper storage,
improper installation, misuse, or which have
been modified or repaired by unauthorized
personnel�
Repair works due to improper use will be
charged at standard rates�
6� STORAGE AND
PRE-INSTAllATION
6.1 STOrAge prOCedure
iMpOrTAnT
Not performing the following procedures will
invalidate the product guarantee.
Normally the optional extension for additional
entry/entries or additional electronic card
are directly mounted on the base ICON 2000 /
ICON 2000 AD by biffi and leaves the factory
in perfect condition� under this condition the
general storage procedure as stated in the
main IOM must be applied�
When the above extensions are shipped
separately for a field upgrading on existing
ICON 2000 / ICON 2000 AD unit this must be
stored in a protected area taking care that
the explosion proof joints are well protected
avoiding any damage to the joint surfaces�
The standard plastic plugs used to protect
the cable entry during the transport is not
explosion proof nor water proof, it just prevent
the entry of undesired objects during transport�
The extension for additional entry/entries or
additional electronic card maintain the same
weatherproof degree of protection as the base
ICON 2000 / ICON 2000 AD� This condition can
only be maintained if the extension is correctly
installed/connected on site and if it has been
correctly stored�
6.2 CHeCkS TO Be perfOrMed BefOre
inSTAllATiOn
before to install the extension for additional
entry/entries or additional electronic card in
an existing unit ICON 2000 / ICON 2000 AD the
following checks are recommended:
- The status of the joint surfaces�
- Status of the threads on the conduit entry�
- Whether the enclosure holding the additional
conduit entry is cracked or broken�