16
Biffi
ICON 2000
InstructIon and operatIng manual
5.7 operatinG the icon 2000 for the
first tiMe
Before attempting to operate the ICON 2000
for the first time, check that the actuator is
correctly mounted on the valve� Place the
3-position selector in Off and switch the
power on� The alphanumeric display shows the
following message for about 3 seconds:
5.8 optional Modules
Additional modules can be plugged in the base
card of the ICON 2000 to provide the following
functions:
5.8.1 fieldbus interface for remote control via
fieldBus
This card allows to connect the ICON 2000 to
fIELDBuS�
The following bus interface cards are available:
- Profibus DPVO
- Profibus DPV1 with or without redundancy
- foundation fieldbus
- LonWorks
- Modbus RTu
A Hardware alarm is generated if the
ICON 2000 was set to be equipped with
bus card, but the card is damaged or missing�
A BuS REPORT is also present in the list of
reports if the card is present (see chapter 6)�
See the specific manuals for instructions and
the setting of the above modules�
Then the new message should be:
according to the configuration present in the
memory�
If the upper line of the display shows
“
alarM off
”, remove the alarm before
going ahead (see paragraph 12�11)�
If the upper line of the display shows
“
warninG off
”, a warning condition
is present� you can go ahead since the
ICON 2000 is working well, but some datum
is not according to the configured parameters
(see paragraph 12�11)�
If the upper line of the display shows
“
int off
”, an Interlock input is active�
If the upper line of the display shows
“
esd on off
”, the ESD input is active�
If the following message appears, the base
card is ICON 2000 v4 type, but the actuator is
equipped with an ICON 2000 v0 series terminal
board� This may happen if the ICON 2000 v4
base card was supplied as a spare card, to
replace the base card of the ICON 2000 v0
series (see the previous revision of instruction
manuals relevant to the ICON 2000 and its
optional modules)�
5.8.2 ain/aout card
With the above card the ICON 2000 is provided
with a 4-20 analog input and a 4-20 mA analog
output� This card should be plugged on the
base card, replacing the “TERMINAL BOARD
ADAPTOR” card supplied as standard� A
Hardware alarm is generated if the ICON 2000
was set to be equipped with an Ain/Aout
card, and the card is damaged or missing�
An Ain/Aout REPORT is also present in the list
of reports if the card is present (see chapter 6)�
or
Set torque limits, position limits and close
direction by means of the “stroke limits
routine” of the “actuator set-up” menu
(see chapter 9)�
When the stroke limits and the configurations
are correct, bring the 3-position selector to
LOCAL and drive the actuator to open or closed
position (see paragraph 5�3)�
Biffi italia
icon2000 v4 ntb
norMal off
stop
norMal
off
r%: xxx.x
Biffi italia
icon2000 v4 otb
Do not operate the actuator without first
checking that the configuration is according to
the required application by using the “VIEW and
SET-uP” features (see chapter 6/10)�