23
Do not turn your system on immediately.
The system can be operated
only after the mortar or self-leveling underlayment has completely cured.
This waiting period is essential to ensure that the mortar or self-leveling
underlayment is properly set. Refer to manufacturer’s instructions to verify the
curing time for the product you are using (generally 28 days).
After
fl
ooring is installed,
turn the system on brie
fl
y to test its operation.
Do not run the system for more than a few minutes before the mortar has
fi
nished curing.
When setting a temperature,
be sure to check the thermal limits of
your chosen
fl
oor covering. Wood and laminate
fl
oorings often have a
recommended maximum of 29°C (84°F) .
Do not exceed this value.
Activating the system.
Depending on the
fl
oor covering and temperature
of the room, it can take some time for the system to warm up. Carefully pull
the heating leads from the wall and check them using a clamp-style ammeter.
Con
fi
rm that the system is drawing current.
Make sure the system is turned off after a maximum of 10 minutes.
Do not re-activate the system until the required time has passed for the
fl
oor mortar to completely cure. Once this curing is
fi
nished, the system is
complete!
>
>
>
>
>
>
07 System Start-Up