Warmset is an electrical product. The appropriate precautions and
care that are associated with electrical installations should be taken.
Always be aware of risks of electric shock,
fi
re, and/or injury to
persons. Please read carefully and observe all precautions listed in
these pages.
Attention!
<
<
<
<
<
<
<
<
Caution
Always
install a Class “A” GFCI or EGFPD circuit breaker with each Warmset
mat installation. Note: All Warmset thermostats come equipped with a built-
in Class “A” GFCI or EGFPD.
Always
use caution when working with tools around Warmset mats. Be
careful not to nick or cut the heating ribbon.
Always
completely embed Warmset mats in minimum 3/8” self-leveling
compound and thinset mortar, or other polymer-modi
fi
ed, cement-based
mortar.
Always
adhere to all power limitations of the breaker, thermostat, and
chosen Warmset Mat. Be sure the Voltage and Current are appropriate for the
system.
Always
install Warmset mats on a dedicated 20 A circuit.
Always
make sure all electrical work is done by quali
fi
ed people in
accordance with local electrical and building codes.
Always
use copper wiring to complete the connections in the Warmset
system.
Always
seek help or clarity if problems arise. If in doubt about any
installation procedures, or if the product appears to be damaged, please
contact Warmset before starting the installation process.
All Installations must be performed by quali
fi
ed personnel
in accordance with all local regulations and building codes.
Thoroughly read and follow the installation instructions and
warnings before beginning installation.
Failure to do so can result in electric shock,
fi
re, property
damage, personal injury, and/or death.
Always