This command edits the User password of the device. The programming
sequence of each User command on the GSM requires a 4 digit user password
in order to secure the device‘s functionality. The default User password is always
―0000‖ and can be change anytime by this command. When User password is
changed, only the program sequence that starts with the new user
password will be accepted.
In this command there is only Edit possibility.
SMS messaging Programming:
User Command 3 -
“User Password” :
*
Edit:
#
0000
#
3
#
1562
Edit
This command enables or disables the buzzer sounds on the device.
In Battery failure or shelf test operation, device informs for its state with the
onboard loud buzzer.
In this command there is only Edit and Ask possibility.
User Command 4 -
“Buzzer function” :
*
Buzzer ON:
#
0000
#
4
#
1
Buzzer OFF:
#
0000
#
4
#
0
Edit
Ask
Ex.:
#
0000
#
4
#
?
*