PELEKIS ELECTRONICS
15
ISO9001/2015
Rev. 1.04 April 2019
SMS Programming Table
Command
Description
Edit - Delete
Ask
USER AUTHORIZED
1
Calling number
#0000#1#...n...,_,...n2..,...n3…*
Example : n =00302102323345
#0000#1#?
2
Low battery call number
#0000#2#6974587393*
Delete : #0000#2#_*
#0000#2#?
3
User password
#0000#3#1E5D*
-
4
Buzzer function
#0000#4#0*(OFF)
#0000#4#1* (ON)
#0000#4#?
5
Incoming Calls
#0000#5#0*(OFF)
#0000#5#1* (ON)
#0000#5#?
6
Ask monitor
-
#0000#6#?
7
Outputs-Relays
#0000#7#R1=1 relay 0n
#0000#7#R1=1 relay off
#0000#7#?
8
Inputs-Optocouplers
#0000#8#0*(AUTO OFF)
#0000#8#1*(AUTO ON)
#0000#8#?
ADMIN AUTHORIZED
20
Admin password
#1111#20#1E5D*
-
21
Auto-run number
#1111#21#6974587393*
Delete : #1111#21#_*
#1111#21#?
22
Voice function
#1111#22#0* (OFF)
#1111#22#1* (ON)
-
23
Ask IMEI
-
#1111#23#?
24
SIM Card notifications
#1111#24#0* (OFF)
#1111#24#1* (ON)
-
Note:
‗ _ ‘ : Variable reset to 0, delete.
‗ * ‘ : All commands must close with
‗ ? ‘ : Ask the content of variable.
‗ # ‘ : Change parameter field.
‗ , ‘ : Change scope of variable if more than one Ex.(
#0000#7#R1=1,r8:0,r7=0,r1=0* )
*
*
*