PELEKIS ELECTRONICS
10
ISO9001/2015
Rev. 1.04 April 2019
In this operation, GSM Gateway device is able to Edit-Delete or Ask stored settings that
define its operation.
The device is always ready to receive SMS messages. These messages are processed
and executed accordingly, if they are valid. (see «PROGRAMMING» section)
Any valid formatted incoming SMS, is answered
with a SMS text ―OK‖ or a text
contains the requested action.
Any invalid formatted SMS, isn‘t answered
with any
SMS
from the device, in order to
avoid unnecessary charges on the SIM card.
SMS programming functions are divided into two categories, which differ in term of
authorization.
These are USER and ADMIN Authorization.
Caution:
Authorization password (User
– Admin) must match the SMS code that is requested.
Incoming SMS :
1
Action not ready
— Send
answer
but has no effect on device.
2
Action not available
— Send no
answer
.
User Actions:
Admin Actions:
Program 4 calling number
2
.
Program admin password.
Program low battery calling number.
Program auto-run calling number
2
.
Program user password.
Program voice function
2
.
Program buzzer function.
Ask IMEI.
Program Incoming call function
1
.
Program SIM Card notifications
2
.
Ask monitor
2
.
Program Outputs-Relays.
Program Inputs-Optocouplers.