Manual 

12 

5.2.6.4 

USB 

 
 
In this menu the type of data transmission is selected. The choices are: 
 

Mass storage (default setting)                                                PCE-MMT I as a mass storage 

Contin.                                                                                    PCE-MMT I transmits continuously 

 

Press 

 to select the desired transmission type. Confirm the selection with

 

5.3 

Settings 

 
“Auto-0-”                                                              factory default settings -> On 
“Measuring frequency”                                   

factory default settings -> 100Hz                              

“AD/DA filter”                                                       factory default settings - >Off 
 

With 

 you can select the desired submenu. Confirm the selection with 

 

 

5.3.1 

“Auto-0-” 

 

With 

 you enter the function for the automatic zeroing when switching. By pressing 

 you confirm 

the selection.  
 
 
When this function is active, the display is set to zero at switching automatically, regardless of the existing 
load. 

5.3.2 

Measuring frequency 

 
The following setting options are available: 
 

2000 Hz

 (maximum value) 

1000

 

Hz

 

  500

 

Hz

 

  400

 

Hz

 

  250

 

Hz

 

  200

 

Hz

 

  160

 

Hz

 

  100

 

Hz

 (factory default setting) 

    50

 

Hz

 

 

With 

 you can set the sampling rate of the analog / digital converter. Confirm with 

 

 
The following setting options are available: 
   
 

OFF 

(no filter; factory default setting) 

F 1 

(the smallest filter level) 

F 2 

 

F 3 

(middle filter level) 

F 4 

 

F 5 

(the highest filter level) 

 
 

With 

 you can select the desired filter. Confirm the selection with

 . 

Содержание PCE-MMT E

Страница 1: ...d Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instruments co...

Страница 2: ...ilter 13 5 4 Factory setup 13 6 Save and transfer the measurement data 13 6 1 Peak values 13 6 2 Curve 14 6 3 Termination of dara saving 14 6 4 Data transfer in mass storage mode 14 6 5 Data transfer...

Страница 3: ...are at any time and without notice Any changes will be reflected in the then published user manuals 2 Safety notes Please read this manual carefully and completely before you use the device for the fi...

Страница 4: ...1 Key functions 4 5 6 7 1 2 3 1 Power button To turn the device on please press the button for 2 3 seconds Then the device starts and displays the connected TEDs measuring cells Notes on TEDs in chap...

Страница 5: ...er mode or the curve recording in a mass storage mode 5 Mode Measure without peak value Zeroing of the indicated force Mode Menu One menu level higher from the submenu Input of the numerical value mov...

Страница 6: ...he mode you need for measurement In the menu item Settings you can carry out the expanded settings The menu item Factory Setup makes it possible to restore the factory default settings or to enter the...

Страница 7: ...values are retained and displayed again when the peak measurement is enabled They will be only overwritten with higher values Curve storage Curve Clicking activates the function curve storage 5 2 1 1...

Страница 8: ...er distance limit value can be set in addition Note The data transfer and storage is automatically stopped when a limit value is exceeded Two symbols on the display above the power indicator show the...

Страница 9: ...d the time limit is considered from curve duration 5 2 3 Display You can adjust display as follows according to your needs Rotate display After pressing you can rotate the display by 180 with the help...

Страница 10: ...ched on measuring instrument as well as when the device is switched on the detected measurement cell information is displayed A new window open which displays the main information of the measurement c...

Страница 11: ...y only in case of battery pack change as the date and time are set at the factory With you can set the time and date The input is activated after the initial pressing of any of both keys Confirm with...

Страница 12: ...the function for the automatic zeroing when switching By pressing you confirm the selection When this function is active the display is set to zero at switching automatically regardless of the existi...

Страница 13: ...filter are though the computational complexity is also higher then For the display device it means that the higher the order of the selected filter the more values are taken into account in the avera...

Страница 14: ...menu item no saving see chapter or when the memory on the SD card is completely full The measurement data transfer through the data streaming remains active 6 4 Data transfer in mass storage mode Data...

Страница 15: ...er switching between force time and force distance curves Note Please always pay attention that the device must be turned on first before it is connected to the started computer If the data transfer d...

Страница 16: ...batteries is shown at any time in the upper right corner of the display If the batteries have reached their maximum service life and no longer have their full power so standard AA batteries or in case...

Страница 17: ...bout 15 a header line Overload appears instead of the force display A mechanical overload protection happens at about 125 of rated load If the overload is withdrawn in time this indication disappears...

Страница 18: ...Lower 1221 Setpoint Input 1222 Mode Sign Absolute 13 Display 131 Rotate 1311 0 180 132 Invert 1321 Normal Inverted 133 Backlight 1331 Power Off Max 134 Contrast 1341 Power Off Max 14 Units 141 N 142 k...

Страница 19: ...em or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 16 Contact If you have any questions about our range of p...

Отзывы: