Introduction 

 
Thank you for purchasing a Tensile and Compressive Force Meter PCE-MMT E from PCE Instruments. 
 

This manual is published by PCE Instruments without any warranty. Our equipment complies with all the 
relevant safety regulations and carries the CE symbol. The CE Declaration of Conformity can be found as 
an attachment. We point explicitly to our general warranty conditions, which can also be found on this 
disk (CD) are and ask for attention. The warranty period of 24 months as described herein does not apply 
to batteries. For this a statutory warranty period is 6 months from the date of delivery. 
 
The warrant expires in case of damage: 
 

 

an intervention by the buyer, the user or unauthorized third party in the device or its software;

 

 

improper handling; especially if the mechanical overloading of the built-in sensor is caused;

 

 

improper operation, storage, force majeure or other external influences occurs. 

 

Improvements and changes to this manual necessitated by typographical errors and inaccuracies can be 
made by the PCE Germany GmbH at any time without notice. 
The PCE Germany GmbH reserves the right to make technical modifications and changes to the device, 
its accessories and software at any time and without notice. Any changes will be reflected in the then 
published user manuals.

 

 

Safety notes 

 
Please read this manual carefully and completely before you use the device for the first time. The device 
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no 
warranty of damages or injuries caused by non-observance of the manual.

 

 
- The device may only be used in approved temperature range  

The opening of the instrument should only be done by qualified personnel of the PCE Instruments 

 

- The instrument should never be placed face down on the user interface (e.g., keyboard side on a table)  
- You should not make technical changes to the device  
- The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner

 

 
This user's handbook is published from PCE Instruments without any guarantee. 
 
We expressly point to our general guarantee terms, they can be found in our general terms of business. 
 

With the present measuring instrument, tensile and compressive forces can be determined up to the 
specified maximum measuring range. Improper use may cause damage to the sensor.

 

 
If you have any questions please contact PCE Instruments. 
 
 

Specification 

 
Measuring accuracy 

 

 

 

 

 0.05% v.E

 

Max. measurement frequency   

 

 

2000 Hz 

Resolution 

 

 

 

 

 

± 50.000 digits

 

Power supply   

 

 

 

 

3 AA NiMh batteries 

 

 

 

Memory 

 

 

 

 

 

2 GB SD memory card   

 

 

 

Visualization 

 

 

 

 

 

Display of measurement curves 

Dimensions 

 

 

 

 

 

75 x 35 x 170 mm

 

 

Содержание PCE-MMT E

Страница 1: ...d Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instruments co...

Страница 2: ...ilter 13 5 4 Factory setup 13 6 Save and transfer the measurement data 13 6 1 Peak values 13 6 2 Curve 14 6 3 Termination of dara saving 14 6 4 Data transfer in mass storage mode 14 6 5 Data transfer...

Страница 3: ...are at any time and without notice Any changes will be reflected in the then published user manuals 2 Safety notes Please read this manual carefully and completely before you use the device for the fi...

Страница 4: ...1 Key functions 4 5 6 7 1 2 3 1 Power button To turn the device on please press the button for 2 3 seconds Then the device starts and displays the connected TEDs measuring cells Notes on TEDs in chap...

Страница 5: ...er mode or the curve recording in a mass storage mode 5 Mode Measure without peak value Zeroing of the indicated force Mode Menu One menu level higher from the submenu Input of the numerical value mov...

Страница 6: ...he mode you need for measurement In the menu item Settings you can carry out the expanded settings The menu item Factory Setup makes it possible to restore the factory default settings or to enter the...

Страница 7: ...values are retained and displayed again when the peak measurement is enabled They will be only overwritten with higher values Curve storage Curve Clicking activates the function curve storage 5 2 1 1...

Страница 8: ...er distance limit value can be set in addition Note The data transfer and storage is automatically stopped when a limit value is exceeded Two symbols on the display above the power indicator show the...

Страница 9: ...d the time limit is considered from curve duration 5 2 3 Display You can adjust display as follows according to your needs Rotate display After pressing you can rotate the display by 180 with the help...

Страница 10: ...ched on measuring instrument as well as when the device is switched on the detected measurement cell information is displayed A new window open which displays the main information of the measurement c...

Страница 11: ...y only in case of battery pack change as the date and time are set at the factory With you can set the time and date The input is activated after the initial pressing of any of both keys Confirm with...

Страница 12: ...the function for the automatic zeroing when switching By pressing you confirm the selection When this function is active the display is set to zero at switching automatically regardless of the existi...

Страница 13: ...filter are though the computational complexity is also higher then For the display device it means that the higher the order of the selected filter the more values are taken into account in the avera...

Страница 14: ...menu item no saving see chapter or when the memory on the SD card is completely full The measurement data transfer through the data streaming remains active 6 4 Data transfer in mass storage mode Data...

Страница 15: ...er switching between force time and force distance curves Note Please always pay attention that the device must be turned on first before it is connected to the started computer If the data transfer d...

Страница 16: ...batteries is shown at any time in the upper right corner of the display If the batteries have reached their maximum service life and no longer have their full power so standard AA batteries or in case...

Страница 17: ...bout 15 a header line Overload appears instead of the force display A mechanical overload protection happens at about 125 of rated load If the overload is withdrawn in time this indication disappears...

Страница 18: ...Lower 1221 Setpoint Input 1222 Mode Sign Absolute 13 Display 131 Rotate 1311 0 180 132 Invert 1321 Normal Inverted 133 Backlight 1331 Power Off Max 134 Contrast 1341 Power Off Max 14 Units 141 N 142 k...

Страница 19: ...em or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 16 Contact If you have any questions about our range of p...

Отзывы: