PCE Instruments PCE-MMT E Скачать руководство пользователя страница 18

Manual 

18 

 

1.  Level 

2.  Level 

3.  Level 

4.  Level 

User 

11

 Memory 

1112

 Function 

1111

 No saving 

1112

 Peak /- 

1113

 Save the curve 

 

 

112

 Quantity 

       Peak values 

1121

 Value Input 

 

 

113

 Time Curve  

1131

 Value Input 

 

 

114

 Delete 

 
 

1141

 Delete Peak value 

1142

 Delete Curve 

1143

 Delete All 

 

 

115

 Browse 

 

 

 

12

 Limit value 

 

121

 Upper 

 

 

1211

 Setpoint->Input 

1212

 Mode->Sign/  

         Absolute 

 

 

122

 Lower 

 

1221

 Setpoint->Input 

1222

 Mode->Sign/ 

         Absolute  

 

 

13

 Display 

 

131

 Rotate 

 

1311

 0° / 180° 

 

 

132

 Invert 

1321

 Normal/Inverted 

 

 

133

 Backlight 

1331

 Power Off ... Max. 

 

 

134

 Contrast 

1341

 Power Off ... Max. 

 

 

14

 Units 

 

141

 N 

 
 

 

 

142

 kN 

 

 

 

143

 MN 

 

 

 

144

 g 

 

 

 

145

 kg 

 

 

 

146

 t 

 

 

 

147

 lb 

 

 

 

15

 System 

 

151

 Date/Time 

 

 

 

152

 Language 

1521 

D / GB / Sp / Fr / I 

 

 

153

 Auto Off 

1531 

Off/1/2/5/10min 

 

 

154

 USB 

1541 

Mass storage 

1542 

continuous 

 

 

 

 

Settings 

21 

Auto-0- 

211 

On/Off 

 

 

22 

Measuring 

frequency 

221 

Selection

 

2221  

2000/1000/500/400/250/200/160/100/50 
Hz 

 

23 

AD/DA-Filter 

231 

Off 

232 

F1 

233 

F2

 

234 

F3

 

235 

F4

 

236 

F5

 

 

 
 
 
 
 
 

15  Disposal 

 
 

Содержание PCE-MMT E

Страница 1: ...d Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instruments co...

Страница 2: ...ilter 13 5 4 Factory setup 13 6 Save and transfer the measurement data 13 6 1 Peak values 13 6 2 Curve 14 6 3 Termination of dara saving 14 6 4 Data transfer in mass storage mode 14 6 5 Data transfer...

Страница 3: ...are at any time and without notice Any changes will be reflected in the then published user manuals 2 Safety notes Please read this manual carefully and completely before you use the device for the fi...

Страница 4: ...1 Key functions 4 5 6 7 1 2 3 1 Power button To turn the device on please press the button for 2 3 seconds Then the device starts and displays the connected TEDs measuring cells Notes on TEDs in chap...

Страница 5: ...er mode or the curve recording in a mass storage mode 5 Mode Measure without peak value Zeroing of the indicated force Mode Menu One menu level higher from the submenu Input of the numerical value mov...

Страница 6: ...he mode you need for measurement In the menu item Settings you can carry out the expanded settings The menu item Factory Setup makes it possible to restore the factory default settings or to enter the...

Страница 7: ...values are retained and displayed again when the peak measurement is enabled They will be only overwritten with higher values Curve storage Curve Clicking activates the function curve storage 5 2 1 1...

Страница 8: ...er distance limit value can be set in addition Note The data transfer and storage is automatically stopped when a limit value is exceeded Two symbols on the display above the power indicator show the...

Страница 9: ...d the time limit is considered from curve duration 5 2 3 Display You can adjust display as follows according to your needs Rotate display After pressing you can rotate the display by 180 with the help...

Страница 10: ...ched on measuring instrument as well as when the device is switched on the detected measurement cell information is displayed A new window open which displays the main information of the measurement c...

Страница 11: ...y only in case of battery pack change as the date and time are set at the factory With you can set the time and date The input is activated after the initial pressing of any of both keys Confirm with...

Страница 12: ...the function for the automatic zeroing when switching By pressing you confirm the selection When this function is active the display is set to zero at switching automatically regardless of the existi...

Страница 13: ...filter are though the computational complexity is also higher then For the display device it means that the higher the order of the selected filter the more values are taken into account in the avera...

Страница 14: ...menu item no saving see chapter or when the memory on the SD card is completely full The measurement data transfer through the data streaming remains active 6 4 Data transfer in mass storage mode Data...

Страница 15: ...er switching between force time and force distance curves Note Please always pay attention that the device must be turned on first before it is connected to the started computer If the data transfer d...

Страница 16: ...batteries is shown at any time in the upper right corner of the display If the batteries have reached their maximum service life and no longer have their full power so standard AA batteries or in case...

Страница 17: ...bout 15 a header line Overload appears instead of the force display A mechanical overload protection happens at about 125 of rated load If the overload is withdrawn in time this indication disappears...

Страница 18: ...Lower 1221 Setpoint Input 1222 Mode Sign Absolute 13 Display 131 Rotate 1311 0 180 132 Invert 1321 Normal Inverted 133 Backlight 1331 Power Off Max 134 Contrast 1341 Power Off Max 14 Units 141 N 142 k...

Страница 19: ...em or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 16 Contact If you have any questions about our range of p...

Отзывы: