8
SAFIR 5L
OPERATION AND ATTENDANCE MANUAL
PG 01-31
Fuel System
Description:
flow rate:
Max. pressure
low-pressure, with constant input flow rate, with twelve
bypass nozzles and throttled output
130±5 l.hour
-1
1,3±0,1 MP
а
Working fuel temperature
-40 ÷ +60 °C
Block of Filter and Servo:
490740.01
-
filter efficiency
12
m
-
signaling of clogging
switches on, when pressure loss in the filter element
reaches 35
9 kP
а
-
filter relief valve
turns on, when pressure loss in the filter element reaches
55
12 kP
а
-
electromagnetic valve
opened when energized, max. current consumption 1,5
А
-
servo-operated valve
current consumption 0-150 m
А
modulation 250 Hz – 500 mV
-
non-return valve
opens when pressure exceeds 10 kP
а
-
thermoregulator
32
С
(89.618
F)
-
air-relief valve
opens at pressure amounting to 20 kP
а
-
slide-valve
adjustment at 100
10 kP
а
Fuel
pump:
490720.01
-
type single
stage,
gear-type
-
filter
63
m
-
delivered quantity
130±5 l.hour
-1
(depended on operation mode)
-
pressure 1,3±0,1
MP
а
Fuel - oil exchanger:
Tubular
Fuel
nozzle:
bypass (with fuel bypassing)
-
number of nozzles:
12
Fuel ramp drainage valve:
DV-1
-
closes at fuel pressure amounting to:
15
+10
kP
а
Combustion chamber drainage valve:
DV-2
-
closes at air pressure amounting to:
36
+2
-8
kP
а
Return fuel filter:
LUN 7616-8
-
filter efficiency
12
m
-
bypass set to
30
5 kP
а