11
SAFIR 5L
OPERATION AND ATTENDANCE MANUAL
PG 01-31
Control and Regulation System
Description:
electronic
Speed transmitter:
LUN 1326.03-8
-
purpose
produces the input signal for electronic control
-
type electromagnetic
-
output voltage
1 V on 2145 Hz
5 %
-
location
on the APU gearbox
-
tooth-wheel with circumferential holes
number of holes: 36
-
conversion ratio rpm
/ Hz 11,668
Temperature Transmitter
-
purpose
-
type
-
number off transmitter
LUN 1371.01-8
produces the input signal for electronic control
Thermocouple CHROMEL-ALUMEL
3
Control
box:
LUN 3594.04
-
purpose
- controls the APU speed according to the mode selected
- controls the function of electric accessories
- type
- performs the APU closing
- digital
-
preset modes
- full operating speed 100 %
51 900 rpm
- idling speed 89 %
46 400 rpm
-
APU protections (levels of setup)
- maximum speed 109 %
56 660 rpm
- sub-speed 79 %
41 200 rpm
- closing during actuation, when the
exhaust gas temperature does not reach
150
С
(302
F) within
13 sec.
- closing of APU during actuation, when
sub-speed (70 %) is not reached within
35 sec.
- high temperature of the exhaust gases is
signalized, when the temperature reaches
850± 15
С
(1562±59
F)
- In case of exceeding the set exhaust gases
temperature - the control box will perform
decrease of turbine speed until reaching of
the set temperature of the exhaust gases.
800 ± 15 °C
(1472±59
F)
Signaling on the control panel in the pilot’s
compartment which will not cause closing of APU:
- rotation speed 89 %
- rotation speed 100 %
-high gas temperature
-clogging of the oil filter
-clogging of the fuel filter
Detailed description of technical characteristic and operating work of the Control Box LUN 3594.04 see Enclosure
No. 1) – document PRP-2011-602-02-801, Technical and operating manual.